Affiliation:
1. private practice in Salò, Italy
2. Burn Unit, Ospedale Cannizzaro Catania, Paternò, Italy
Abstract
Abstract
Background
This retrospective study reports on the early experience of a private surgical center with Motiva Ergonomix SilkSurface SikSurface breast implants.
Objectives
to examine the incidence of complications and satisfaction levels in women who received primary and revision breast augmentation or augmentation-mastopexy with this device.
Methods
356 consecutive patients received Motiva Ergonomix breast implants from April 2014 to October 2018 by 3 different surgeons and were followed-up for a minimum of 12 months. Complications were assessed by measuring the rate of rupture, capsular contracture, malposition, late seroma, double capsule, reoperation, symmastia, ptosis, extrusion, and infection. Satisfaction with aesthetic results was assessed by both surgeon and patient, using the Likert scale.
Results
Only six major complications were observed in these 356 patients (712 implants). One unilateral implant ptosis (“bottoming out”) at 12 months (0.14 %) and 2 capsular contractures (0.28 %), one at 14 months and the other at 2 years. At all time-points, 98% of the patients were “extremely satisfied or very satisfied” with the aesthetic results and surgeons categorized the outcomes as “very important or important improvement” in 96% of the cases.
Conclusions
Motiva Ergonomix SilkSurface devices provided high patient satisfaction up to more than 5 years postoperatively with very few complications. These data are consistent with other reports in the literature. The observed favorable outcomes might be attributed, at least in part, to Motiva Ergonomix’s bio-engineered “cell-friendly” surface.
Publisher
Oxford University Press (OUP)
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献