3-Dimensional Printed Alternative to the Standard Synthetic Flocked Nasopharyngeal Swabs Used for Coronavirus Disease 2019 Testing

Author:

Decker Summer J1,Goldstein Todd A2,Ford Jonathan M1ORCID,Teng Michael N1,Pugliese Robert S3,Berry Gregory J2,Pettengill Matthew3,Silbert Suzane4,Hazelton Todd R1,Wilson Jason W1,Shine Kristy3,Wang Zi-Xuan3,Hutchinson Morgan3,Castagnaro Joseph2,Bloom Ona E2,Breining Dwayne A2,Goldsmith Barbara M3,Sinnott John T1,O’Donnell Donna Gentile3,Crawford James M2,Lockwood Charles J1,Kim Kami1

Affiliation:

1. University of South Florida, Morsani College of Medicine, Tampa, Florida, USA

2. Northwell Health System, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, New Hyde Park, New York, USA

3. Thomas Jefferson University, Philadelphia, Pennsylvania, USA

4. Tampa General Hospital, Tampa, Florida, USA

Abstract

Abstract Background Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes coronavirus disease 2019 (COVID-19), can be detected in respiratory samples by real-time reverse transcriptase polymerase chain reaction (RT-PCR) or other molecular methods. Accessibility of diagnostic testing for COVID-19 has been limited by intermittent shortages of supplies required for testing, including flocked nasopharyngeal (FLNP) swabs. Methods We developed a 3-dimensional printed nasopharyngeal (3DP) swab as a replacement of the FLNP swab. The performance of 3DP and FLNP swabs were compared in a clinical trial of symptomatic patients at 3 clinical sites (n = 291) using 3 SARS-CoV-2 emergency use authorization tests: a modified version of the Centers for Disease Control and Prevention (CDC) RT-PCR Diagnostic Panel and 2 commercial automated formats, Roche Cobas and NeuMoDx. Results The cycle threshold—C(t)—values from the gene targets and the RNase P gene control in the CDC assay showed no significant differences between swabs for both gene targets (P = .152 and P = .092), with the RNase P target performing significantly better in the 3DP swabs (P < .001). The C(t) values showed no significant differences between swabs for both viral gene targets in the Roche cobas assay (P = .05 and P = .05) as well as the NeuMoDx assay (P = .401 and P = .484). The overall clinical correlation of COVID-19 diagnosis between all methods was 95.88% (Kappa 0.901). Conclusions The 3DP swabs were equivalent to standard FLNP in 3 testing platforms for SARS-CoV-2. Given the need for widespread testing, 3DP swabs printed onsite are an alternate to FLNP that can rapidly scale in response to acute needs when supply chain disruptions affect availability of collection kits.

Publisher

Oxford University Press (OUP)

Subject

Infectious Diseases,Microbiology (medical)

Reference25 articles.

1. An interactive web-based dashboard to track COVID-19 in real time;Du,2020

2. An interactive web-based dashboard to track COVID-19 in real time;Dong;Lancet Infect Dis,2020

3. Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1;van Doremalen;N Engl J Med,2020

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3