Adsorption of Therapeutic and Recreational Drugs During Prolonged Storage of Plasma Samples in Gel Separator Tubes

Author:

Shepard Cara L1ORCID,Bliumkin Liora2

Affiliation:

1. Toxicology Section, Centre of Forensic Sciences, 25 Morton Shulman Avenue, Toronto, ON M3M 0B1, Canada

2. Laboratory Services Section, Centre of Forensic Sciences, 25 Morton Shulman Avenue, Toronto, ON M3M 0B1, Canada

Abstract

Abstract Hospital samples collected in gel separator tubes are often submitted to forensic toxicology laboratories for analysis in impaired driving and death investigations. Drug adsorption to the gel separator material may lead to underestimation of the drug concentration present at the time of sample collection, potentially affecting the interpretation of analytical results. Using liquid chromatography-tandem mass spectrometry (LC-MS-MS), decreases in plasma concentration of 53 drugs and metabolites relevant to forensic toxicology casework were investigated in samples stored in BD Vacutainer® PSTTM tubes for up to 3 months. After storage for only 1 day, approximately 50% of the drugs and metabolites had significantly lower concentrations in plasma separation tubes (PSTs) compared to non-gel tubes (up to 27% lower). After storage for 3 months, approximately 75% of the drugs and metabolites had significantly lower concentrations in PSTs compared to non-gel tubes (up to 69% lower). Fentanyl, carfentanil, ketamine, diphenhydramine and several antidepressants were among the drugs most susceptible to adsorption. Central nervous system stimulants (e.g., methamphetamine and amphetamine) as well as naturally-occurring and semi-synthetic opioids (e.g., morphine, hydromorphone and oxycodone) were among the drugs least susceptible to adsorption and displayed only minimal relative decreases in concentration (if any) over the 3-month sample storage period. The potential for decreases in drug concentration due to adsorption of drugs to the gel material should be considered for toxicological interpretation based on the analysis of a sample collected in a gel separator tube.

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3