Simultaneous Quantitation of Seven Phenethylamine-Type Drugs in Forensic Blood and Urine Samples by UHPLC–MS-MS

Author:

Yang Chu-An12,Liu Hsiu-Chuan2,Liu Ray H3,Lin Dong-Liang2,Wu Shu-Pao1ORCID

Affiliation:

1. Department of Applied Chemistry, National Chiao Tung University, Hsinchu 30010, Taiwan

2. Department of Forensic Toxicology, Institute of Forensic Medicine, Ministry of Justice, New Taipei City 235016, Taiwan

3. Department of Criminal Justice, University of Alabama at Birmingham, Birmingham, AL 35294, USA

Abstract

Abstract Abuse of new psychoactive substances (NPS) has become a health and social issue of global concern. p-Methoxyamphetamine (PMA)/p-methoxymethamphetamine (PMMA) with fluoro- or chloro-derivatives of amphetamine and methamphetamine were among the most common drugs found in specimens from fatal cases in Taiwan during the January 2011 to December 2018 period. A liquid–liquid extraction sample preparation protocol with highly sensitive ultra-high performance liquid chromatography–tandem mass spectrometry approach was developed for the simultaneous analysis of seven phenethylamine-type drugs—PMA, PMMA, p-methoxyethylamphetamine, 4-fluoroamphetamine (4-FA), 4-fluoromethamphetamine (4-FMA), 4-chloroamphetamine (4-CA) and 4-chloromethamphetamine (4-CMA)—in postmortem blood and urine specimens. Separation by liquid chromatography was performed by Agilent Zorbax SB-Aq column. Tandem mass spectrometry was operated in Agilent Jet Stream Technology electrospray ionization in positive-ion multiple reaction monitoring mode. An analytical methodology was evaluated using drug-free blood and urine after fortification with 100–2,000 ng/mL of the seven target analytes. Average extraction recoveries were >80%; slightly higher ion suppression was observed for PMA and 4-CA; intra-/inter-day precision (% coefficient of variation) and accuracy were in the ranges of 0.52–12.3% and 85–110%, respectively. Limit of detection and lower limit of quantitation for these seven analytes were both in the 0.5–5 ng/mL range. Interference and carryover were not significant. This relatively simple methodology was found effective and reliable for routine identification and quantitation of these seven analytes in postmortem and antemortem blood and urine specimens received in 2018. Analytical data obtained from these actual cases indicated the following: (i) compared to findings reported during the 2007–2011 period, the use of substituted phenethylamine-type drugs decreased in 2018; (ii) ketamine and 7-aminonimetazepam (the main metabolite of nimetazepam) were the most common co-ingested substances in specimens containing PMA/PMMA, 4-FA/4-FMA, or 4-CA/4-CMA; and (iii) in drug fatalities, the concentration of PMA was significantly higher than the concentration of PMMA in both urine and blood, while the reverse was true in urine specimens from antemortem cases.

Funder

Ministry of Justice, Taiwan

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

Reference44 articles.

1. NPS related deaths in Chinese Taipei: detection technology and toxicological findings;Liu

2. The PMMA epidemic in Norway: comparison of fatal and non-fatal intoxications;Vevelstad;Forensic Science International,2012

3. Forensic electrochemistry: simultaneous volumetric detection of MDMA and its fatal counterpart “Dr Death” (PMA);Cumba;Analytical Methods,2016

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献