Comparison of Breath- and Blood-Alcohol Concentrations in a Controlled Drinking Study

Author:

Skaggs Lindsey12ORCID,Heizler Amy1,Kalscheur Diane2,Miles Amy2,Barkholtz Heather M123ORCID

Affiliation:

1. Division of State Patrol, Bureau of Transportation Safety, Chemical Testing Section, Wisconsin Department of Transportation, 3502 Kinsman Blvd., Madison, WI 53704, USA

2. Wisconsin State Laboratory of Hygiene, Forensic Toxicology Division, University of Wisconsin-Madison, 2601 Agricultural Dr., Madison, WI 53718, USA

3. School of Pharmacy, Pharmaceutical Sciences Division, University of Wisconsin-Madison, 777 Highland Ave., Madison, WI 53705, USA

Abstract

Abstract In this work, 114 volunteers were dosed with 80-proof liquor to produce peak blood-alcohol concentration (BAC) or breath-alcohol concentration (BrAC) of 0.040–0.080 g/100 mL blood or g/210 L breath. This was followed by a 30 minute deprivation period before simultaneous blood and breath samples were collected and the alcohol concentration quantified. BAC was determined by gas chromatography with flame ionization detection and BrAC by a dual-sensor Intox EC/IR II instrument. Paired Student t-tests showed that differences between paired blood- and breath-alcohol results differed significantly. Results from these two measurement methods are highly correlated and, on average, measured BAC was 11.3% greater than BrAC. There were 10 instances of BrAC being greater than the corresponding BAC, and the average difference between these two values was 0.0059 g/100 mL. Agreement plots of coupled BAC and BrAC revealed a mean bias of 0.00754 g/100 mL and 95% limits of agreement (LOA) at −0.00705 and 0.0221 g/100 mL. Once BrAC values were truncated to the hundredths place as required by Wisconsin state statute, only three participants had greater BrAC than corresponding BAC, with an average difference between these values of 0.008 g/100 mL. Agreement plots with truncated BrAC values gave a mean bias of 0.0120 g/100 mL and 95% LOA at −0.00344 and 0.0275 g/100 mL. Data showed that typically, blood samples had greater alcohol concentrations than corresponding breath values. Differences were exacerbated by Wisconsin’s statutory requirement that reported breath alcohol measurements be truncated to the hundredths place, whereas blood has no corresponding mandate.

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

Reference27 articles.

1. Traffic Crash Database: Final Year-End Crash Statistics;Wisconsin Department of Transportation,2020

2. Report of the subcommittee on alcohol: technology, pharmacology, and toxicology committee on alcohol and other drugs national safety council;Harding,1999

3. The relationship between blood alcohol concentration (BAC) and breath alcohol concentration (BrAC): a review of the evidence;Jones;Road Safety Web Publication,2010

4. Quantitative studies on alcohol tolerance in man. The influence of ethyl alcohol on sensory, motor and psychological functions referred to blood alcohol in normal and habituated individuals;Goldberg;Acta Physiologica Scandinavica,1943

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司