Evaluation of Sonicate Fluid Culture Cutoff Points for Periprosthetic Joint Infection Diagnosis

Author:

Alvarez Otero Judith1,Karau Melissa J1,Greenwood-Quaintance Kerryl E1,Abdel Matthew P2,Mandrekar Jay3,Patel Robin14ORCID

Affiliation:

1. Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic , Rochester, Minnesota , USA

2. Department of Orthopedic Surgery, Mayo Clinic , Rochester, Minnesota , USA

3. Department of Quantitative Health Sciences, Mayo Clinic , Rochester, Minnesota , USA

4. Division of Public Health, Infectious Diseases, and Occupational Medicine, Department of Medicine, Mayo Clinic , Rochester, Minnesota , USA

Abstract

Abstract Introduction Implant sonication is useful for recovery of periprosthetic joint infection (PJI) pathogens in culture, but exact cutoff points for definition of clinically significant sonicate fluid culture results vary from study to study. The aim of this study was to define ideal sonicate fluid culture cutoff points for PJI diagnosis. Methods Sonicate fluid cultures from hip and knee prosthesis components removed between February 2007 and December 2020 were studied. Prosthesis components were placed in solid containers in the operating room; in the clinical microbiology laboratory, 400 mL Ringer's solution was added, and containers subjected to vortexing, sonication and then vortexing, followed by centrifugation. Concentrated sonicate fluid was plated on aerobic and anaerobic solid media, and culture results reported semiquantitatively, as no growth, <20, 20–50, 51–100, or >100 CFU/10 mL sonicate fluid. Sonicate cultures from cement spacers and cultures yielding more than 1 microorganism were excluded. Sensitivity and specificity of each cutoff point was evaluated. Results A total of 1448 sonicate fluid cultures were evaluated, 68% from knees and 32% from hips. PJI was present in 644 (44%) cases. Sensitivity of sonicate culture was 75.0% at <20 CFU/10 mL, 55.3% at ≥20 CFU/10 mL, 46.9% at >51 CFU/10 mL, and 39.8% at >100 CFU/10 mL. Specificity was 78.2%, 99.8%, 100%, and 100%, at the 4 cutoff points, respectively. Conclusions A cutoff point for sonicate fluid culture positivity of ≥20 CFU/10 mL is suitable for PJI diagnosis.

Funder

National Institute of Arthritis and Musculoskeletal and Skin Diseases

National Institutes of Health

Publisher

Oxford University Press (OUP)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3