Nasopharyngeal Panbio COVID-19 Antigen Performed at Point-of-Care Has a High Sensitivity in Symptomatic and Asymptomatic Patients With Higher Risk for Transmission and Older Age

Author:

Masiá Mar12,Fernández-González Marta1ORCID,Sánchez Manuel3,Carvajal Mar1,García José Alberto1,Gonzalo-Jiménez Nieves4,Ortiz de la Tabla Victoria5,Agulló Vanesa1,Candela Inmaculada6,Guijarro Jorge7,Gutiérrez José Antonio8,de Gregorio Carlos3,Gutiérrez Félix12ORCID

Affiliation:

1. Infectious Diseases Unit, Hospital General Universitario de Elche, Elche, Alicante, Spain

2. Clinical Medicine Department, Universidad Miguel Hernández, San Juan de Alicante, Spain

3. Department 20th Health Authority, Consellería de Sanitat, Generalitat Valenciana, Elche, Alicante, Spain

4. Microbiology Service, Hospital General Universitario de Elche, Elche, Alicante, Spain

5. Microbiology Service, Hospital Universitario de San Juan, Alicante, Spain

6. Santa Pola Primary Care Center, Alicante, Spain

7. Altabix Primary Care Center, Elche, Alicante, Spain

8. Emergency Department, Hospital General Universitario de Elche, Elche, Alicante, Spain

Abstract

Abstract Background Performance of point-of-care tests in different clinical scenarios and on different samples remains undetermined. We comprehensively evaluated the performance of the nasopharyngeal Panbio COVID-19 Ag Rapid Test Device. Methods This is a prospective study that includes consecutive patients attending 3 primary care centers (PCCs) and an emergency department. The antigen test was performed at point-of-care in nasopharyngeal and nasal swabs and in saliva. Positive percent agreement (PPA) and negative percent agreement (NPA) were calculated with the reverse-transcription polymerase chain reaction (RT-PCR) assay as reference standard. Results Of 913 patients included, 296 (32.3%) were asymptomatic and 690 (75.6%) came from the PCC. Nasopharyngeal swabs were collected from 913 patients, nasal swabs were collected from 659 patients, and saliva was collected from 611 patients. The RT-PCR was positive in 196 (21.5%) nasopharyngeal samples (NPS). Overall, PPA (95% CI) in NPS was 60.5% (53.3–67.4), and it was lower in nasal swabs (44.7%) and saliva (23.1%). Test performance in NPS was largely dependent on the cycle threshold (Ct) in RT-PCR, with PPA of 94% for Ct ≤25 and 80% for Ct <30. In symptomatic patients, the PPA was 95% for Ct ≤25, 85% for Ct <30, and 89% for the symptom triad of fever, cough, and malaise. Performance was also dependent on age, with a PPA of 100% in symptomatic patients >50 years with Ct <25. In asymptomatic patients, the PPA was 86% for Ct <25. In all cases, NPA was 100%. Conclusions The nasopharyngeal Panbio COVID-19 Ag test performed at point-of-care has a good sensitivity in symptomatic patients with Ct <30 and older age. The test was useful to identify asymptomatic patients with lower Ct values.

Funder

Plan Nacional Research + Development + Innovation

Instituto de Salud Carlos III - Subdirección General de Evaluación y Fondo Europeo de Desarrollo Regional

Instituto de Salud Carlos III

Publisher

Oxford University Press (OUP)

Subject

Infectious Diseases,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3