Safety and Efficacy of Submuscular Implantation With Resterilized Cardiac Implantable Electronic Device in Patients With Device Infection: A Retrospective Observational Study in Taiwan

Author:

Yu Chia-Meng12,Yu Chieh-Ming12,Yao Wen-Teng12,Lee Ying-Hsiang23,Liao Feng-Ching23,Chien Chih-Yin45,Chang Sheng-Hsiung23,Liao Hung-Wei1,Chen Yu-Fan12,Huang Wen-Chen12,Tung Kwang-Yi12,Tsai Ming-Feng12

Affiliation:

1. Division of Plastic Surgery, Department of Surgery, Mackay Memorial Hospital, Taipei City, Taiwan

2. Department of Medicine, MacKay Medical College, New Taipei, Taiwan

3. Cardiovascular Center, MacKay Memorial Hospital, Taipei City, Taiwan

4. Department of Nursing, MacKay Junior College of Medicine, Nursing, and Management, Taipei, Taiwan

5. National Taipei University of Nursing and Healthy Sciences, Taipei, Taiwan

Abstract

Abstract Background Reuse of cardiac implantable electronic devices (CIEDs) can reduce the cost of using these expensive devices. However, whether resterilized CIEDs will increase the risk of reinfection in patients with previous device infection remains unknown. The aim of the present study is to compare the reinfection rates in patients who had initial CIED infection and underwent reimplantation of resterilized CIEDs or new devices. Methods Data from patients with initial CIED infection who received debridement of the infected pocket and underwent reimplantation of new or resterilized CIEDs at MacKay Memorial Hospital, Taipei, Taiwan, between January 2014 and June 2019 were retrospectively analyzed. Patient characteristics, relapse rates of infection, and potential contributing factors to the infection risk were examined. Results Twenty-seven patients with initial CIED infection and reimplanted new CIEDs (n = 11) or resterilized CIEDs (n = 16) were included. During the 2-year follow-up, there were 1 (9.1%) and 2 (12.5%) infection relapses in the new and resterilized CIED groups, respectively. No relapse occurred for either group if the lead was completely removed or cut short. The median duration between debridement and device reimplantation in patients with infection relapse vs patients without relapse was 97 vs 4.5 days for all included patients, and 97 vs 2 days and 50.5 vs 5.5 days for the new and resterilized CIED groups, respectively. Conclusions Subpectoral reimplanting of resterilized CIEDs in patients with previous device infection is safe and efficacious. With delicate debridement and complete extraction of the leads, the CIED pocket infection relapse risk can be greatly decreased.

Publisher

Oxford University Press (OUP)

Subject

Infectious Diseases,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3