Affiliation:
1. Department of Thoracic Surgery, Aichi Cancer Center Hospital, Nagoya, Japan
Abstract
Abstract
OBJECTIVES
To conduct robotic lung resections (RLRs) with views similar to those in open-thoracotomy surgery (OTS), we adopted a vertical port placement and confronting upside-down monitor setting: the robotic open-thoracotomy-view approach (OTVA). We herein discuss the procedures for emergency rollout and conversion from the robotic OTVA to OTS or video-assisted thoracoscopic surgery (VATS).
METHODS
We retrospectively reviewed the cases of 88 patients who underwent RLR with three-arm OTVA using the da Vinci Xi Surgical System between February 2019 and July 2021. Robotic ports were vertically placed along the axillary line, and 2 confronting monitors and 2 assistants were positioned on each side of the patient. Three possible conversions were prepared: (i) emergency thoracotomy using an incision along the ribs in a critical situation, (ii) cool conversion using vertical incision thoracotomy in a calmer condition and (iii) conversion to confronting VATS. All staff involved in the surgery repeatedly rehearsed the emergency rollout in practice.
RESULTS
No emergent or cool conversion to OTS occurred. Two patients (2.3%) experienced confronting VATS conversions. One patient underwent an urgent conversion for a moderate haemorrhage from a pulmonary artery branch during left upper lobectomy in the introduction phase. Another patient underwent a calmer conversion during an extended RS6 + S10a segmentectomy, where staples could not be inserted appropriately due to lung lacerations. In all patients, postoperative courses were uneventful.
CONCLUSIONS
The OTVA setting is a possible option for RLRs. This report describes the emergent rollout and subsequent conversion procedures for this method.
Publisher
Oxford University Press (OUP)
Subject
Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献