False lumen/true lumen wall pressure ratio is increased in acute non-A non-B aortic dissection

Author:

Kimura Naoyuki1ORCID,Nakamura Masanori2,Takagi Reiya2,Mieno Makiko Naka3,Yamaguchi Atsushi1ORCID,Czerny Martin4,Beyersdorf Friedhelm4,Kari Fabian Alexander4,Rylski Bartosz4

Affiliation:

1. Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University , Saitama, Japan

2. Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology , Nagoya, Japan

3. Department of Medical Informatics, Center for Information, Jichi Medical University , Shimotsuke, Japan

4. Department of Cardiovascular Surgery, University Heart Centre Freiburg, University of Freiburg , Freiburg, Germany

Abstract

Abstract OBJECTIVES We aimed to determine whether non-A non-B aortic dissection (AD) differs in morphologic and haemodynamic properties from type B AD. METHODS We simulated and compared haemodynamics of patients with acute type B or acute non-A non-B AD by means of computational fluid dynamics. Wall pressure and wall shear stress (WSS) in both the true lumen (TL) and false lumen (FL) at early, mid- and late systole were evaluated. Morphology, WSS and the FL/TL wall pressure ratio were compared between groups. RESULTS Nineteen patients (type B, n = 7; non-A non-B, n = 12) were included. The median age (51 [46, 67] vs 53 [50, 63] years; P = 0.71) and a complicated course (14% vs 33%; P = 0.6) did not differ between the type B group and the non-A non-B group. However, the median entry tear width was increased in the non-A non-B group (9.7 [7.3, 12.7] vs 16.3 [11.9, 24.9] mm; P = 0.010). Streamlines showed, in patients with non-A non-B AD, blood from the TL flowed into the FL via the entry tear. Prevalence of a FL/TL wall pressure ratio >1.0 (type B versus non-A non-B) at early, mid- and late systole was 57% vs 83% (P = 0.31), 43% vs 83% (P = 0.13) and 57% vs 75% (P = 0.62), respectively. WSS did not differ between the groups. CONCLUSIONS The increased FL/TL wall pressure ratio observed during systole in non-A non-B AD may beget a complicated presentation.

Funder

Grant-in-Aid for Scientific Research C

Ministry of Education, Culture, Sports, Science and Technology

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3