Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively

Author:

Szecel Delphine12ORCID,Lamberigts Marie1,Rega Filip1,Verbrugghe Peter1ORCID,Dubois Christophe1,Meuris Bart1ORCID

Affiliation:

1. Department of Cardiovascular Sciences—Cardiac Surgery, Katholieke Universiteit Leuven , Leuven, Belgium

2. Department of Cardiovascular Surgery, CHU de Liège , Liège, Belgium

Abstract

Abstract OBJECTIVES The aim of this study was to evaluate the impact of changing the sizing strategy in aortic valve replacement using the Perceval sutureless prosthesis on haemodynamic outcomes and postoperative pacemaker implantation. METHODS Retrospective analysis of patients implanted with the Perceval valve between 2007 and 2019 was performed by comparing patients implanted before the modification of sizing strategy (OLD group) and after (NEW group). The outcome parameters evaluated were the implanted prosthesis size, haemodynamical profile and postoperative pacemaker implantation. RESULTS The entire patient cohort (784 patients) consisted of 52% female patients, with a mean age of 78.53 [standard deviation (SD): 5.8] years and a mean EuroSCORE II of 6.3 (range 0.7–76). In 55.5% of cases, surgery was combined. The NEW cohort had more male patients (54.6% vs 43.4%) (P = 0.002). Mean implanted valve size, corrected for body surface area, was significantly lower in the NEW cohort (13.1, SD: 1.4 vs 13.5, SD: 1.4 mm/m2, P < 0.001). The 30-day mortality was 3.4%. Peak and mean transvalvular gradients at discharge were significantly lower in the NEW versus OLD groups: 24.4 mmHg (SD: 9.2) versus 28.4 mmHg (SD: 10.3) (P < 0.001) and 13.6 mmHg (SD: 5.3) versus 15.5 mmHg (SD: 6.0) (P < 0.001). The mean effective opening area and the indexed effective opening area, respectively, increased from 1.5 cm2 (SD: 0.5) and 0.85 cm2/m2 (SD: 0.27) in the OLD group to 1.7 cm2 (SD: 0.5) and 0.93 cm2/m2 (SD: 0.30) in the NEW group (P < 0.001). No difference was found in paravalvular leakage ≥1/4. Centrovalvular leakage ≥1/4 significantly decreased from 18% to 7.9% (P < 0.001). With the new sizing, the new postoperative pacemaker implantation rate decreased significantly from 11% to 6.1% (P = 0.016). CONCLUSIONS Correct sizing of sutureless aortic valves is crucial to obtain the best possible haemodynamics and avoid complications.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3