Usability, performance and safety of a new device for degenerative mitral regurgitation: in vivo chronic evaluation

Author:

Zeitani Jacob1,Chiariello Giovanni Alfonso23ORCID,Shofti Rona4,Bruno Piergiorgio23,Massetti Massimo23,Alfieri Ottavio5ORCID

Affiliation:

1. Neurosciences and Rehabilitation Department, University of Ferrara , Ferrara, Italy

2. Cardiovascular Sciences Department, Agostino Gemelli Foundation Polyclinic IRCCS , Rome, Italy

3. Catholic University of The Sacred Heart , Rome, Italy

4. Department of Biomedical Engineering, Technion-Israel Institute of Technology , Haifa, Israel

5. Department of Cardiac Surgery, San Raffaele University Hospital , Milan, Italy

Abstract

Abstract OBJECTIVES This study aimed to evaluate the usability, performance and safety of an innovative mitral valve device in the chronic setting characterized by an intraventricular bridge, which enables artificial chordae anchoring and/or direct posterior leaflet fixation. METHODS Ten female sheep were employed and underwent device implantation. Any interference of the device with leaflet motion, ease of device use, correct chordae length estimation and implantation were evaluated. Post-procedural valve competence and device performance were verified by periodic postoperative echocardiograms and laboratory examinations. Following euthanasia, gross anatomy and histology evaluation of the hearts and valves were performed to detect tissue abnormalities and inflammation reaction related to the device. RESULTS The procedure was successfully completed in all 10 sheep. Lengths of the 2 chordae implanted were 23 (21.5–24) mm and 23 (22.5–24) mm. The time required to suture both pairs of the artificial chordae was 2.7 ± 0.7 min. At the 3-month follow-up, left ventricular function was normal. The transvalvular peak pressure gradient was 9 (7.5–10) and the mean gradient was 4 (3.5–4) mmHg. Upon necropsy and histological evaluation, no damage to left ventricle wall, valve leaflets, chordae and papillary muscles and absence of thrombus formation and inflammatory reaction were observed. Radiological images showed neither fracture of the device nor calcifications. Laboratory tests showed no signs of haemolysis. CONCLUSIONS In vivo late tests confirmed the ease of correct chordal length estimation prior to implantation, short operative time and usability in flailed anterior leaflet repair. The absence of negative impact of the device on mitral leaflets motion, function and structure and successful repair might suggest that the device would be useful in complex degenerative mitral disease.

Funder

Ministry of Science and Technology of Israel

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Do we need new devices for surgical mitral valve repair?;Interactive CardioVascular and Thoracic Surgery;2022-06-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3