Graft flow assessment and early coronary artery bypass graft failure: a computed tomography analysis

Author:

D’Alessio Andrea1ORCID,Akoumianakis Ioannis2ORCID,Kelion Andrew3,Terentes-Printzios Dimitrios3,Lucking Andrew3,Thomas Sheena2ORCID,Verdichizzo Danilo1ORCID,Keiralla Amar4,Antoniades Charalambos23,Krasopoulos George1ORCID

Affiliation:

1. Department of Cardiothoracic Surgery, Oxford University Hospital NHS Foundation Trust, Oxford, UK

2. Cardiovascular Medicine Division, University of Oxford, Oxford, UK

3. Department of Cardiology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK

4. Department of Cardiac Anesthesia, Oxford University Hospitals NHS Foundation Trust, Oxford, UK

Abstract

Abstract OBJECTIVES We evaluated graft patency by computed tomography and explored the determinants of intraoperative mean graft flow (MGF) and its contribution to predict early graft occlusion. METHODS One hundred and forty-eight patients under a single surgeon were prospectively enrolled. Arterial and endoscopically harvested venous conduits were used. Intraoperative graft characteristics and flows were collected. Graft patency was blindly evaluated by a follow-up computed tomography at 11.4 weeks (median). RESULTS Graft occlusion rate was 5.2% (n = 22 of 422; 8% venous and 3% arterial). Thirteen were performed on non-significant proximal stenosis while 9 on occluded or >70% stenosed arteries. Arterial and venous graft MGF were lower in females (Parterial = 0.010, Pvenous = 0.009), with median differences of 10 and 13.5 ml/min, respectively. Arterial and venous MGF were associated positively with target vessel diameter ≥1.75 mm (Parterial = 0.025; Pvenous = 0.002) and negatively with pulsatility index (Parterial < 0.001; Pvenous < 0.001). MGF was an independent predictor of graft occlusion, adjusting for EuroSCORE-II, pulsatility index, graft size and graft type (arterial/venous). An MGF cut-off of 26.5 ml/min for arterial (sensitivity 83.3%, specificity 80%) and 36.5 ml/min for venous grafts (sensitivity 75%, specificity 62%) performed well in predicting early graft occlusion. CONCLUSIONS We demonstrate that MGF absolute values are influenced by coronary size, gender and graft type. Intraoperative MGF of >26.5 ml/min for arterial and >36.5 ml/min for venous grafts is the most reliable independent predictor of early graft patency. Modern-era coronary artery bypass graft is associated with low early graft failure rates when transit time flow measurement is used to provide effective intraoperative quality assurance.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3