Validation of large animal models in mechanical valve research: a histologic comparison

Author:

Van Hecke Manon1ORCID,Langenaeken Tom2,Rega Filip2,Roskams Tania1,Meuris Bart2

Affiliation:

1. Department of Pathology, University Hospitals Leuven , Leuven, Belgium

2. Department of Cardiac Surgery, University Hospitals Leuven , Leuven, Belgium

Abstract

Abstract OBJECTIVES Mechanical valves still require life-long anticoagulation. Preclinical animal testing is a crucial step in the assessment of valves; however, the chosen animal model should be carefully considered, and a well-controlled animal model of mechanical valve thrombosis has not been established yet. In this study, a histopathologic comparison was performed to evaluate the representativity of pigs and sheep as large animal models in bileaflet mechanical valve thrombosis research. METHODS 10 pigs and 8 sheep were implanted with a bileaflet mechanical valve in pulmonary position. During follow-up, no anticoagulative therapy was administered. Pigs were sacrificed between 14 and 38 days for explantation and assessment of the valve. Sheep were sacrificed between 71 and 155 days. Thrombus samples were processed and (immuno)histochemical stainings were applied. A pathologist evaluated the samples morphologically and semiquantitatively and compared these samples to available slides from 3 human patients who underwent redo surgery for acute bileaflet mechanical valve thrombosis, caused by insufficient anticoagulation. RESULTS All pigs showed macroscopically evident thrombi on the mechanical valve surface at sacrifice. In contrast, none of the sheep showed any sign of thrombus formation. Histology showed a high fibrin content in thrombi of both human and porcine cases (3/3 vs 8/10). Porcine thrombi showed more cellular organization (0/3 vs 6/10), more calcification (0/3 vs 9/10) and more endothelialization (0/3 vs 6/10). Inflammatory cells were present in all samples and were considered physiological. CONCLUSIONS Contrary to sheep, pigs develop thrombi on their mechanical valves in the short-term if no anticoagulation is administered. Histologic comparison of human and porcine thrombi shows comparable findings. The pig model might serve interestingly for further research on valve thrombosis, if it shows not to be an overly aggressive model.

Funder

Experimental Research Fund Cardiovascular Surgery

Publisher

Oxford University Press (OUP)

Reference30 articles.

1. Mechanical versus bioprosthetic aortic valve replacement;Head;Eur Heart J,2017

2. Dabigatran versus warfarin in patients with mechanical heart valves;Eikelboom;N Engl J Med,2013

3. Apixaban or warfarin in patients with an On-X mechanical aortic valve;Wang;NEJM Evid,2023

4. The current state of in vivo pre-clinical animal models for heart valve evaluation;Gallegos;J Heart Valve Dis,2005

5. The medtronic parallel valve and the lessons learned;Bodnar;J Heart Valve Dis,1996

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3