The effect of the conduit size on middle-term outcomes in patients with extracardiac total cavopulmonary connection

Author:

Hirose Keiichi1,Ikai Akio1ORCID,Ito Hiroki1,Ishidou Motonari1,Toritsuka Daisuke1,Nakamura Yuji1,Watanabe Seito1,Nakatani Eiji2ORCID,Sakamoto Kisaburo1ORCID

Affiliation:

1. Department of Cardiovascular Surgery, Mt. Fuji Shizuoka Children’s Hospital , Shizuoka, Japan

2. Division of Statistical Analysis, Research Support Center, Shizuoka General Hospital , Shizuoka, Japan

Abstract

Abstract OBJECTIVES The 18- and 16-mm conduits in extracardiac total cavopulmonary connection (eTCPC) were reported to be optimal based on energy loss and flow stagnation at the relatively early phase. However, because the artificial conduit lacks growth potential, we have recently encountered some cases in which the conduit needs to be changed several years after eTCPC. These cases prompted us to reconsider the surgical strategy for eTCPC. METHODS We reviewed our 20-year single-centre experience with eTCPC patients (n = 256) to compare the 18-mm conduit (n = 195) and 16-mm conduit (n = 61) in terms of mortality and morbidity. RESULTS The 16-mm conduit was used significantly more frequently in patients whose main chamber was right ventricle (P < 0.001). There was also a significant difference in preoperative inferior vena cava pressure (P = 0.008). There was a significant difference in the actuarial rate of freedom from late-occurring complications, including mortality, between the 2 groups (P = 0.003). There was a significant difference in the actuarial rate of reoperation-free survival (P = 0.042); however, there was no significant difference in resurgical intervention for the conduit (P = 0.333). In multivariate analysis, preoperative inferior vena cava pressure was an independent predictor for late-occurring complications (hazard ratio 1.19; P = 0.026). Conduit size (18 or 16 mm) itself was not an independent predictive factor for late-occurring complications (P = 0.690). CONCLUSIONS The mid-term clinical outcomes in patients who underwent eTCPC were excellent with low mortality. Preoperative inferior vena cava pressure was the only predictive risk factor for postoperative morbidity, and the 16 mm conduit was not predictive thereof.

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3