Effect of preservation solution and distension pressure on saphenous vein’s endothelium

Author:

Pimentel Matheus Duarte1ORCID,Lobo Filho José Glauco1,Lobo Filho Heraldo Guedis1,de Castro Miguel Emílio2,Pinheiro Paiva Sergimar Kennedy2,Silva Matos João Igor3,Mesquita Fernandes Matheus Augusto3,Fechine Jamacaru Francisco Vagnaldo3

Affiliation:

1. Department of Surgery, Federal University of Ceará , Fortaleza, Brazil

2. Department of Metallurgical Engineering and Materials (DEMM) and Analytical Center, Federal University of Ceará , Fortaleza, Brazil

3. Federal University of Ceará , Fortaleza, Brazil

Abstract

Abstract OBJECTIVES Approaches to improve saphenous vein (SV) patency in coronary artery bypass graft (CABG) surgery remain relevant. This study aimed to evaluate the effects of different preservation solutions and different pressures of intraluminal distention on the endothelium of SV segments in CABG. METHODS Forty-two SV segments obtained from 12 patients undergoing CABG were divided into 7 groups. Group 1 (control) was prepared without preservation or intraluminal distension, while the other 6 groups were preserved in autologous heparinized autologous arterial blood or normal saline (NS), with distention pressures 30, 100 and 300 mmHg. To assess the effects of using these solutions and pressures on the endothelium, the grafts were analysed by scanning electron microscopy, with the measurement of endothelial damage degree. RESULTS Segments in group 1 showed minimal endothelial damage. SV grafts preserved with NS had significantly greater endothelial damage both compared to the control group and compared to groups preserved with autologous arterial blood (P < 0.001). Segments distended with pressures up to 100 mmHg showed less damage when compared to those distended at 300 mmHg, with the ones subjected to higher pressures presenting a maximum degree of damage, with considerable loss and separation of endothelial cells, extensive foci of exposure of the basement membrane and numerous fractures of the intimate layer, without differences regarding the solution used. CONCLUSIONS Preparation of SV using NS and with intraluminal distension pressures above 100 mmHg is factors related to increased damage to the venous endothelium.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3