Initial experience with the new type A arch dissection stent: restoration of supra-aortic vessel perfusion

Author:

Montagner Matteo1ORCID,Kofler Markus1ORCID,Heck Roland1ORCID,Buz Semih12,Starck Christoph12ORCID,Kurz Stephan13ORCID,Falk Volkmar1234ORCID,Kempfert Jörg12

Affiliation:

1. Department of Cardiothoracic and Vascular Surgery, German Heart Center, Berlin, Germany

2. DZHK (German Centre for Cardiovascular Research), Partner Site, Berlin, Germany

3. Department of Cardiovascular Surgery, Charité—Berlin Medical School, Berlin, Germany

4. Department of Health Sciences and Technology, Translational Cardiovascular Technologies, Institute of Translational Medicine, Swiss Federal Institute of Technology (ETH) Zurich, Zurich, Switzerland

Abstract

Abstract OBJECTIVES The goal of the present study is to investigate changes in supra-aortic vessel perfusion after implantation of the non-covered Ascyrus Medical Dissection Stent (AMDS) for surgical treatment of acute type A aortic dissection. METHODS From 2017 to 2020, 16 consecutive patients treated with AMDS and involvement (dissection to total occlusion) of at least 1 supra-aortic vessel were included in the study. Centre-line based computed tomography measurements of true, false and total lumen area using Terarecon software were performed before and after surgery. Changes in the true lumen area were indexed to the entire vessel area. The paired sample t-test was used to assess the significance of the observed differences. RESULTS Analysis of supra-aortic vessels and the descending aorta showed significant improvement in true lumen perfusion after the AMDS was implanted. The indexed true lumen area increased postoperatively by 72%, 112% and 30% in the innominate, right and left common carotid arteries, respectively. Total occlusions of both common carotid arteries recovered completely after surgical treatment. The proximal- and the mid-descending aorta showed a 78% and 48% improvement of the indexed true lumen area, respectively. CONCLUSIONS Arch repair using AMDS shows promising results in the treatment of acute type A aortic dissection. Quantitative measurements of true and false lumen perfusion demonstrated a significant increase in true lumen area and a 100% regression of totally occluded supra-aortic branches. Further examination in a larger cohort of patients and comparison with isolated hemiarch repair are needed to confirm positive vascular remodelling after an AMDS implant.

Funder

Ascyrus Medical

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Reference22 articles.

1. Stroke after emergent surgery for acute type A aortic dissection: predictors, outcome and neurological recovery;Dumfarth;Eur J Cardiothorac Surg,2018

2. Surgery for type A aortic dissection in patients with cerebral malperfusion: results from the International Registry of Acute Aortic Dissection;Sultan;J Thorac Cardiovasc Surg,2019

3. The impact of pre-operative malperfusion on outcome in acute type A aortic dissection: results from the GERAADA Registry;Czerny;J Am Coll Cardiol,2015

4. Patients with type A acute aortic dissection presenting with major brain injury: should we operate on them?;Di Eusanio;J Thorac Cardiovasc Surg,2013

5. Acute type A dissection in octogenarians: does emergency surgery impact in-hospital outcome or long-term survival?;Dumfarth;Eur J Cardiothorac Surg,2017

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3