Transcatheter mitral valve replacement: tissue in-growth after 4 weeks

Author:

Lutter Georg12,Bax Lennart13ORCID,Liu Yazhou12,Hansen Jan-Hinnerk4ORCID,Frank Derk4,Freitag-Wolf Sandra5,Simionescu Agneta6,Sathananthan Janarthanan7,Puehler Thomas12ORCID

Affiliation:

1. Department of Experimental Cardiac Surgery and Heart Valve Replacement, Christian-Albrechts-University of Kiel, School of Medicine, UKSH, Kiel, Germany

2. Department of Cardiovascular Surgery, Christian-Albrechts-University of Kiel, School of Medicine, UKSH, Kiel, Germany

3. Department of Cardiac and Vascular Surgery, Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany

4. Medical center Schleswig-Holstein, Campus Kiel, Kiel, Germany

5. Institute of Medical Informatics and Statistics, Kiel University, Kiel, Germany

6. Department of Bioengineering, Clemson University, Clemson, SC, USA

7. Centre for Heart Valve Innovation, St Paul’s Hospital, University of British Columbia, Vancouver, BC, Canada

Abstract

Abstract OBJECTIVES Tissue reaction to transcatheter mitral valve replacement in the mitral annulus remains to be elucidated. METHODS Trileaflet porcine pericardial valves were sewn onto self-expanding d-shaped nitinol stents, which were delivered transapically and in an off-pump fashion into the mitral position of 10 pigs. After at least 4 weeks of follow-up, gross pathological assessment and histological examination were performed. The specimens were stained with Movat’s pentachrome, Elastica-van-Gieson and von Kossa staining. The leucocytes, B cells, T cells or macrophages were detected by specific immunohistochemical staining. RESULTS Proper stent positioning in the mitral annulus was achieved in 9/10 animals. Nine of 10 animals survived the desired observation period. In all but one, the mitral valve stent was well integrated into the left atrium and perpendicularly embedded into the annulus by 85 ± 24%. One animal had minor fractures in the nitinol struts and another animal showed tearing of 1 of 4 tethers. Histological examination demonstrated no major tissue reaction with the nitninol struts but well-preserved overall structures around the mitral annulus in 8/9 cases. CONCLUSIONS This is the first report demonstrating good in-growth of transcatheter-delivered anatomically shaped mitral valve stents after at least 4 weeks of follow-up. Histological examination demonstrated progressive healing and neointimalization.

Funder

DZHK

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Unusual Postoperative Course After Tendyne Implantation;Circulation: Cardiovascular Imaging;2022-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3