Safety and effectiveness of a transaortic approach for TAVI: procedural and midterm outcomes of 265 consecutive patients in a single centre

Author:

Romano Mauro1ORCID,Daprati Andrea2ORCID,Saitto Guglielmo2ORCID,Tizzano Francesco1,Le Houérou Daniel1,Donzeau-Gouge Patrick1,Farge Arnaud1,Lefèvre Thierry3,Hovasse Thomas3,Garatti Andrea2ORCID

Affiliation:

1. Department of Cardiovascular Surgery and Transcatheter Heart and Vascular Therapies, Institut Cardiovasculaire Paris Sud, Institut Hospitalier Jacques Cartier, Massy, France

2. Department of Cardiac Surgery, Policlinico S. Donato Hospital, S. Donato Milanese, Milan, Italy

3. Department of Cardiology, Institut Cardiovasculaire Paris Sud, Institut Hospitalier Jacques Cartier, Massy, France

Abstract

Abstract OBJECTIVES Transcatheter aortic valve implantation with a transaortic approach (TAo-TAVI) is an alternative to transapical or femoral access. We studied the procedural and midterm efficacy and safety of TAo-TAVI with Edwards Sapien XT and Medtronic CoreValve devices. METHODS Among 901 patients receiving TAVI since 2006, 265 consecutive patients underwent TAo-TAVI between January 2011 and September 2014. Procedural and midterm results were evaluated according to Valve Academic Research Consortium-2 criteria. RESULTS The mean age was 83 ± 5 years. Sapien XT and CoreValve were used in 191 (72.1%) and 74 (27.9%) patients, respectively. Full sternotomy made elective concomitant off-pump coronary artery bypass grafting possible in 38 patients (14.3%) with severe coronary artery disease unsuitable for percutaneous coronary intervention. The device success rate was 95.5%. Postprocedural paravalvular leak  ≥2/4 was observed in 16 patients (6.4%). Emergency open chest surgery was required in 10 patients (3.8%) (3 aortic dissections, 3 valve embolizations, 2 LMCA occlusions, 1 aortic annulus rupture and 1 aortic rupture). Cerebrovascular accidents occurred in 3 patients (1.1%). Transfusions  ≥4 units were required in 36 patients (13.6%). New pacemakers were implanted in 26 patients (9.8%). Thirty-day and 1-year mortality were 8.7% and 16.2%, respectively. Mean follow-up duration was 24 ± 6 months. At 3 years, freedom from all-cause death was 80% ± 4%. New York Heart Association class <III included 81% (n = 172) of patients alive and without prosthetic echocardiographic dysfunction at follow-up (mean gradient 10.5 ± 5.6 mmHg). CONCLUSION The TAo-TAVI approach confirms its safety and effectiveness with satisfactory procedural and midterm outcomes with both currently available devices.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3