Abstract OBJECTIVES The short-term results of video-assisted thoracoscopic surgical ablation (VTSA) with box lesion have been highly variable, and the actual efficacy requires clarification through longer follow-ups. We aimed to report which patients might benefit more from VTSA with box lesion by longer follow-up. METHODS From September 2010 to November 2016, patients with atrial fibrillation (AF) who underwent VTSA with box lesion were screened. All enrolled patients visited the outpatient clinic and underwent 24-h Holter monitoring at 3, 6 and 12 months after surgery and annually thereafter. RESULTS A total of 91 consecutive patients [age, 58.0 (interquartile interval from 52.0 to 62.0) years; male, 71.4%] with paroxysmal (67%) or persistent/long-standing persistent (33%) AF were enrolled. After a median follow-up of 48 months (interquartile interval from 36 to 60 months), freedom from atrial tachyarrhythmias without antiarrhythmic drugs (AADs) was 76.5%, 66.0% and 66.0% for paroxysmal AF and 58.6%, 47.8% and 34.2% for persistent/long-standing persistent AF at 12, 36 and 60 months, respectively (P = 0.017). The preoperative left atrial diameter >40 mm (hazard ratio: 2.837, 95% confidence interval: 1.408–5.716; P = 0.004) and age >50 years (hazard ratio: 2.927, 95% confidence interval: 1.359–6.305; P = 0.006) were associated with recurrences of atrial tachyarrhythmias. In patients with paroxysmal AF and left atrial diameter ≤40 mm (n = 43), freedom from atrial tachyarrhythmias without AADs was 81.4%, 74.3% and 74.3% at 12, 36 and 60 months, respectively. CONCLUSIONS In patients with paroxysmal AF and left atrial diameter ≤40 mm, 5-year freedom from atrial tachyarrhythmias without AADs was 74.3%, which was better than that in patients with left atrial diameter >40 mm. A larger sample size and improved study design are needed to confirm our conclusions.

Funder

Ministry of Science and Technology of China

Prevention and Control Project of Major Chronic Non-infection Disease

Beijing Municipal Commission of Science and Technology

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Reference29 articles.

1. Atrial fibrillation: current knowledge and future directions in epidemiology and genomics;Magnani;Circulation,2011

2. Secular trends in incidence of atrial fibrillation in Olmsted County, Minnesota, 1980 to 2000, and implications on the projections for future prevalence;Miyasaka;Circulation,2006

3. ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association of Cardio-Thoracic Surgery (EACTS);Hindricks;Eur Heart J,2020

4. The Society of Thoracic Surgeons 2017 clinical practice guidelines for the surgical treatment of atrial fibrillation;Badhwar;Ann Thorac Surg,2017

5. Nonpulmonary vein foci: do they exist? Pacing and clinical electrophysiology;Shah;Pacing Clin Electrophysiol,2003

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3