Annular and subvalvular dynamics after extracellular matrix mitral tube graft implantation in pigs

Author:

Tjørnild Marcell J123ORCID,Carlson Hanse Lisa12,Skov Søren N12,Poulsen Karen B12,Sharghbin Mona12,Benhassen Leila L12,Røpcke Diana M12,Nielsen Sten L12,Hasenkam J Michael124

Affiliation:

1. Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark

2. Department of Clinical Medicine, Aarhus University Hospital, Aarhus, Denmark

3. Department of Orthopaedic Surgery, Randers Regional Hospital, Denmark

4. Department of Surgery, University of the Witwatersrand, Johannesburg, South Africa

Abstract

Abstract OBJECTIVES Entire mitral valve reconstruction with an extracellular matrix tube graft is a potential candidate to overcome the current limitations of mechanical and bioprosthetic valves. However, clinical data have raised concern with respect to patch failure. The aim of our study was to evaluate the impact of extracellular matrix mitral tube graft implantation on mitral annular and subvalvular regional dynamics in pigs. METHODS A modified tube graft design made of 2-ply extracellular matrix was used (CorMatrix®; Cardiovascular Inc., Alpharetta, GA, USA). The reconstructions were performed in an acute 80-kg porcine model (N = 8), where each pig acted as its own control. Haemodynamics were assessed with Mikro-Tip pressure catheters and mitral annular and subvalvular geometry and dynamics with sonomicrometry. RESULTS Catheter-based peak left atrial pressure and pressure difference across the mitral and aortic valves in the reconstructions were comparable to the values seen in the native mitral valves. Also comparable were maximum mitral annular area (755 ± 100 mm2), maximum septal-lateral distance (29.7 ± 1.7 mm), maximum commissure–commissure distance (35.0 ± 3.4 mm), end-systolic annular height-to-commissural width ratio (10.2 ± 1.0%) and end-diastolic interpapillary muscle distance (27.7 ± 3.3 mm). Systolic expansion of the mitral annulus was, however, observed after reconstruction. CONCLUSIONS The reconstructed mitral valves were fully functional without regurgitation, obstruction or stenosis. The reconstructed mitral annular and subvalvular geometry and subvalvular dynamics were found in the same range to those in the native mitral valve. A regional annular ballooning effect occurred that might predispose to patch failure. However, the greatest risk was found at the papillary muscle attachments.

Funder

Lundbeck Foundation

Danish Heart Foundation

Graduate School, Health, Aarhus University

Helga and Peter Korning Foundation

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3