Effects of a medium cut-off (Theranova®) dialyser on haemodialysis patients: a prospective, cross-over study

Author:

Cozzolino Mario1ORCID,Magagnoli Lorenza1,Ciceri Paola2,Conte Ferruccio1,Galassi Andrea1

Affiliation:

1. Renal Division, ASST Santi Paolo e Carlo, Department of Health Sciences, University of Milan, Milan, Italy

2. Renal Research Laboratory, Department of Nephrology, Dialysis and Renal Transplant, Fondazione Ca’ Granda IRCCS, Ospedale Maggiore Policlinico, Milan, Italy

Abstract

Abstract Background Despite significant advances in haemodialysis (HD) in recent decades, current dialysis techniques are limited by inadequate removal of uraemic solutes such as middle molecules and protein-bound uraemic toxins. Novel medium cut-off (MCO) membrane or ‘expanded haemodialysis’ (HDx) provides diffusive removal of conventional and large middle molecular weight uraemic toxins, with marginal albumin leak. Methods This prospective, open-label, controlled, cross-over pilot study compared HDx (novel MCO membrane Theranova® 400) and conventional HD in 20 prevalent HD patients. Biochemical, dialysis adequacy and safety measures (adverse events, infections and hospitalization frequency) were recorded. Ten patients underwent conventional HD high-flux dialyser and 10 patients underwent HDx for 3 months, and the patients then switched and received the other treatment for a further 3 months. Results Treatment with HDx was associated with a significant reduction in serum albumin concentration [median (interquartile range) reduction −0.45 g/dL (−0.575 to −0.05); P = 0.025]. However, median albumin levels were ≥3.5 g/dL and no patients had clinical symptoms of hypoalbuminaemia or needed intravenous albumin administration. The number of infections was lower in patients treated with HDx (n = 7/19) compared with patients treated with HD (n = 14/20; P = 0.03). Patients treated with HDx had reduced levels of interleukin (IL)-1β (from 0.06 ± 0.02 pg/mL versus 0.28 ± 0.18 pg/mL with HD) and IL-6 (6.45 ± 1.57 pg/mL versus 9.48 ± 2.15 pg/mL), while tumour necrosis factor-α levels remain unchanged. Conclusions This study demonstrates that the chronic use of the novel MCO dialyser Theranova® appears to be safe and well-tolerated, without serious side effects or hypoalbuminaemia, as well as fewer infections. These results need to be confirmed in larger randomized clinical trials.

Funder

Baxter

Publisher

Oxford University Press (OUP)

Subject

Transplantation,Nephrology

Reference26 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3