Collection Tubes Can Cause False Elevations in Occupational and Clinical Evaluation of Antimony Exposure

Author:

Yang Yifei K12ORCID,Genesi Bryce2,Adams Austin H2

Affiliation:

1. Department of Pathology, School of Medicine, University of Utah , 201 Presidents’ Circle, Salt Lake City, UT 84112, USA

2. ARUP Laboratories , 500 Chipeta Way, Salt Lake City, UT 84108, USA

Abstract

Abstract Occupational exposure to antimony has become rare in the past decades due to antimony mine closures and technological improvement in antimony processing plants in the USA. Although antimony’s ubiquitous presence in plasticwares does not pose known health risk, it can present as a potential contaminant to antimony analysis for occupational exposure assessment. To understand the level of antimony contamination from plastic collection devices, we evaluated two different whole-blood plastic collection tubes that are routinely used for trace and toxic element assessment: royal blue BD Vacutainer® EDTA tube and Greiner VACUETTE® trace elements sodium heparin tube. We analyzed how different fill volumes may impact the concentrations of antimony detected. Although both collection tubes can introduce antimony contaminations to nitric acid and neutral buffer rinse, the Greiner heparin tube introduces a significantly lower amount of antimony to freshly collected whole-blood samples compared to the BD EDTA tube. When patients’ samples are collected with BD EDTA tubes, they would exhibit elevated antimony concentrations that can be interpreted as potential antimony exposure. We conclude that the royal blue BD EDTA plastic tube is not suitable to evaluate blood antimony levels, and laboratories need to validate their own alternative sources when the glass tubes are not available.

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

Reference18 articles.

1. Biomonitoring Summary: Antimony,2017

2. Occupational exposure to antimony compounds;McCallum;Journal of Environmental Monitoring,2005

3. A health hazard evaluation of antimony exposure in fire fighters;de Perio;Journal of Occupational and Environmental Medicine,2010

4. Pseudo-outbreak of antimony toxicity in firefighters - Florida, 2009;Centers for Disease, C. and Prevention;MMWR. Morbidity and Mortality Weekly Report,2009

5. Response of antimony distribution in street dust to urban road traffic conditions;Chang;Journal of Environmental Management,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3