LC–MS-MS Determination of Cytostatic Drugs on Surfaces and in Urine to Assess Occupational Exposure

Author:

Lema-Atán José Ángel1,Lendoiro Elena1ORCID,Paniagua-González Lucía1,Cruz Angelines1,López-Rivadulla Manuel1,de-Castro-Ríos Ana1ORCID

Affiliation:

1. Toxicology Service, Institute of Forensic Sciences, University of Santiago de Compostela , Santiago de Compostela, Spain

Abstract

Abstract The ever-increased usage of cytostatic drugs leads to high risk of exposure among healthcare workers. Moreover, workers are exposed to multiple compounds throughout their lives, leading to cumulative and chronic exposure. Therefore, multianalyte methods are the most suitable for exposure assessment, which minimizes the risks from handling cytostatic drugs and ensures adequate contamination containment. This study describes the development and full validation of two liquid chromatography–tandem mass spectrometry methods for the detection of gemcitabine, dacarbazine, methotrexate, irinotecan, cyclophosphamide, doxorubicinol, doxorubicin, epirubicin, etoposide, vinorelbine, docetaxel and paclitaxel in working surfaces and urine samples. The urine method is the first to measure vinorelbine and doxorubicinol. For surfaces, limits of detection (LOD) and limits of quantification (LOQ) were 5–100 pg/cm2, and linearity was achieved up to 500 pg/cm2. Inaccuracy was between −11.0 and 8.4%. Intra-day, inter-day and total imprecision were <20%, except for etoposide and irinotecan (<22.1%). In urine, LOD and LOQ were 5–250 pg/mL, with a linear range up to 1,000–5,000 pg/mL. Inaccuracy was between −3.8 and 14.9%. Imprecision was <12.4%. Matrix effect was from −58.3 to 1,268.9% and from −66.7 to 1,636% in surface and urine samples, respectively, and extraction efficiency from 10.8 to 75% and 47.1 to 130.4%, respectively. All the analytes showed autosampler (6°C/72 h), freezer (–22°C/2 months) and freeze/thaw (three cycles) stability. The feasibility of the methods was demonstrated by analyzing real working surfaces and patients’ urine samples. Contamination with gemcitabine, irinotecan, cyclophosphamide, epirubicin and paclitaxel (5–4,641.9 pg/cm2) was found on biological safety cabinets and outpatients’ bathrooms. Analysis of urine from patients under chemotherapy identified the infused drugs at concentrations higher than the upper LOQ. These validated methods will allow a comprehensive evaluation of both environmental and biological contamination in hospital settings and healthcare workers.

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3