HPLC–ESI–HRMS2 Determination of N-(2-Hydroxyethyl)-l-valyl-l-leucine in Human Urine: Method Validation

Author:

Hanzlíková Iveta1,Mráz Jaroslav1ORCID,Tvrdíková Monika1,Chrástecká Hana1,Moulisová Alena2ORCID,Linhart Igor3

Affiliation:

1. Centre of Occupational Health, National Institute of Public Health , Šrobárova 49/48, Prague 100 00, Czech Republic

2. Centre of Toxicology and Health Safety, National Institute of Public Health , Šrobárova 49/48, Prague 100 00, Czech Republic

3. Department of Organic Chemistry, Faculty of Chemical Technology, University of Chemistry and Technology Prague , Technická 1905, Prague 166 28, Czech Republic

Abstract

Abstract Biomonitoring of human exposure to reactive electrophilic chemicals such as ethylene oxide (EO) has been commonly based on the determination of adducts with N-terminal valine in blood protein globin, but a systematic search has also been undertaken to find surrogate markers enabling non-invasive sampling. Recently, N-(2-hydroxyethyl)-L-valyl-L-leucine (HEVL) has been identified as an ultimate cleavage product of EO-adducted globin in the urine of occupationally exposed workers. Herein, full validation of the analytical procedure consisting of solid-phase extraction of HEVL from urine samples (2 mL) followed by high-performance liquid chromatography–electrospray ionization–high-resolution mass spectrometry determination using deuterium-labeled HEVL as an internal standard (IS) is described. Method limit of quantitation is 0.25 ng/mL, and its selectivity is excellent as demonstrated by the invariable ratio of the qualifier and quantifier ion intensities across diverse urine samples and synthetic standard. The linear calibration model was applicable over the whole concentration range tested (0.25–10 ng/mL). The method accuracy assessed as a recovery of HEVL using a spiking experiment was 98–100%. Within-day precision of the method ranged from 1.8% to 3.0%, while the results from consecutive analytical runs conducted within 1 week or within 10–150 weeks differed in the range of 2.2–9.7%. The stability study on urine samples (−20°C up to 3 years, freeze-and-thaw up to 10 cycles) as well as on aqueous solutions (5°C up to 4 months) indicated no relevant changes in HEVL concentration (≤4%) over the time tested. Analytical responses of both HEVL and IS correlated with urinary creatinine as an index of matrix composition, but this matrix effect was mostly eliminated using the HEVL/IS peak area ratio, attaining the IS-normalized relative matrix effect <3%. In conclusion, the method complied successfully with the bioanalytical method validation criteria, making it a reliable tool for HEVL determination in human biomonitoring.

Funder

Ministerstvo Zdravotnictví Ceské Republiky

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

Reference17 articles.

1. Carcinogen macromolecular adducts and their measurement;Poirier;Carcinogenesis,2000

2. Protein adducts: quantitative and qualitative aspects of their formation, analysis and applications;Törnqvist;Journal of Chromatography B,2002

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3