Affiliation:
1. Department of Cardiology, Odense University Hospital , Odense , Denmark
Abstract
Abstract
Background
Bioresorbable scaffolds (BRS) have been proposed as an alternative to drug-eluting stents (DES), offering radial support during the early phases of healing, while potentially reducing the risk of long-term complications. A magnesium-based BRS (MgBRS) has shown promising results after implantation. However, there is a lack of knowledge regarding the long-term outcomes.
Case summary
A 62-year-old man with hypertension, dyslipidaemia, family history of ischaemic heart disease, and previous myocardial infarction, presented with non-ST-elevation myocardial infarction (NSTEMI). Six years prior, he also had a NSTEMI and a mid-left anterior descending artery (LAD) lesion was treated with a 3.0/25 mm MgBRS. Post-implantation optical coherence tomography (OCT) revealed proximal edge dissection, and a second MgBRS 3.0/15 mm was implanted. Optical coherence tomography of the scaffold-treated segment was performed after 6 and 12 months with no sign of restenosis. The current angiogram showed a restenosis in the previously MgBRS-treated segment in LAD. Optical coherence tomography showed a plaque rupture in a thin cap fibro-atheroma and scaffold remnants. The lesion was pre-dilated and stented with a 3.0/20 mm DES and post-dilated with a 3.5 mm non-compliant balloon.
Discussion
Most cases of late scaffold failure showed acquired mal-apposition, which also can be related to the degrading process, or uncovered struts, none of which were seen in our case at 6 or 12 months. This case represents an insight into the vascular healing and potential mechanisms for failure of the MgBRS, with serial OCT recording at implantation, and after 6 months, 12 months, and 6 years.
Publisher
Oxford University Press (OUP)
Reference15 articles.
1. Bioresorbable scaffolds: a complex journey to the “promised land”;Colombo;JACC Cardiovasc Interv,2017
2. Comparison of clinical outcomes between Magmaris and Orsiro drug eluting stent at 12 months: pooled patient level analysis from BIOSOLVE II-III and BIOFLOW II trials;Hideo-Kajita;Int J Cardiol,2020
3. Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial;Haude;Lancet,2016
4. One- and two-year clinical outcomes of treatment with resorbable magnesium scaffolds for coronary artery disease: the prospective, international, multicentre BIOSOLVE-IV registry;Wlodarczak;EuroIntervention,2023
5. Comparison of a bioresorbable, magnesium-based sirolimus-eluting stent with a permanent, everolimus-eluting metallic stent for treating patients with acute coronary syndrome: the PRAGUE-22 study;Toušek;Cardiovasc Drugs Ther,2022
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Aspirin/Ticagrelor;Reactions Weekly;2024-08-31