Successful removal of a circular mapping catheter which perforated the pulmonary vein during cryoballoon ablation by lateral thoracotomy: a case report

Author:

Yoshizawa Reisuke1ORCID,Owada Shingen1ORCID,Sawa Yohei1,Deguchi Hiroyuki2

Affiliation:

1. Division of Cardiology, Department of Internal Medicine, Iwate Medical University School of Medicine, 2-1-1 Idaidori, Yahaba-cho, Shiwa-gun, Iwate Prefecture 028-3695, Japan

2. Department of Thoracic Surgery, Iwate Medical University School of Medicine, 2-1-1 Idaidori, Yahaba-cho, Shiwa-gun, Iwate Prefecture 028-3695, Japan

Abstract

Abstract Background Serious complications may occur during cryoballoon ablation (CBA). However, pulmonary vein (PV) perforation by a circular mapping catheter and the strategy for removing the catheter remain poorly understood. Case summary A 40-year-old male presented with palpitations 2 years ago and was diagnosed with paroxysmal atrial fibrillation 5 months ago. He underwent CBA for paroxysmal atrial fibrillation. After isolation of the left PV, a circular mapping catheter was advanced in the right inferior pulmonary vein (RIPV), and single freeze was performed. After isolation of the PV, the catheter tip was immobile and could not be withdrawn with significant resistance. Computed tomography showed that the catheter tip perforated the posterior basal vein (V10) of the RIPV and remained in the right lower lobe, along with intrapulmonary haemorrhage. The patient underwent surgery via right lateral thoracotomy to remove the catheter. The RIPV was peeled to the periphery to expose the V10. The catheter perforated the vessel wall in the middle of the V10 and entered the pulmonary parenchyma. A microincision on the lung parenchyma covering the surface of the catheter tip was performed, and the circular distal portion of the catheter was cut. The entire catheter (i.e. shaft and proximal portion) was successfully removed from the transseptal catheter. Discussion Surgical approach was performed for the management of PV perforation caused by a circular mapping catheter. This case may assist in troubleshooting and problem-solving in case such an event occurs again during procedures in the future.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine

Reference12 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3