Affiliation:
1. Department of Cardiac Surgery, Medical University of Innsbruck , Anichstrasse 35, A-6020 Innsbruck , Austria
Abstract
Abstract
Background
Failing bioprosthesis is an emerging issue due to (i) a shift towards liberal bioprosthesis implantation instead of mechanical prosthesis and (ii) an ageing population. Management of high-risk patients with bioprosthesis degeneration remains challenging.
Case summary
An 82-year-old patient with history of aortic and mitral valve replacement six years before presents with severe dyspnoea. Echocardiograpic assessment reveals (i) structural valve degeneration of the mitral prosthesis (severe stenosis and regurgitation) with concomitant major annular calcifications and (ii) structural valve degeneration of the aortic prosthesis with low-flow, low-gradient restenosis. Due to mitral annular calcifications, the risk of double valve re-replacement and the age of the patient conventional reoperation was deemed very high. The patient is evaluated for transapical double valve implantation. This option is rejected due to the high risk of left ventricular outflow obstruction. The patient is treated with an open transcatheter double valve-in-valve procedure at the following sequence: leaflet resection of the mitral bioprosthesis, mitral valve implantation and fixation under direct view, leaflet resection of the aortic bioprosthesis, and valve frame cracking and aortic valve implantation under direct view. Post-bypass echocardiography shows neither left ventricular outflow tract obstruction nor paravalvular leak or prosthesis dysfunction. The patient is extubated on the first post-operative day and transferred to normal care unit.
Discussion
Open transcatheter double valve-in-valve replacement for degenerated bioprostheses on the arrested heart might be a valuable alternative to treat selected high-risk patients with bioprosthetic valve degeneration.
Publisher
Oxford University Press (OUP)
Subject
Cardiology and Cardiovascular Medicine
Reference12 articles.
1. Bioprosthetic heart valves, thrombosis, anticoagulation, and imaging surveillance;Bax;JACC Cardiovasc Interv,2017
2. Degeneration of bioprosthetic heart valves: update 2020;Kostyunin;J Am Heart Assoc,2020
3. Predictors of haemodynamic structural valve deterioration following transcatheter aortic valve implantation with latest-generation balloon-expandable valves;Tobias;EuroIntervention,2020
4. Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging;Lancellotti;Eur Heart J Cardiovasc Imaging,2016
5. Aortic bioprosthetic valve durability;Rodriguez-Gabella;J Am Coll Cardiol,2017