Ablation of atrial flutter in a patient after Fontan procedure: a case report of challenging access to the common atrium

Author:

Maslova Vera1ORCID,Demming Thomas1,Nonnenmacher Marc2,Voges Inga2,Lyan Evgeny1

Affiliation:

1. Department of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein , Arnold-Heller str. 3 , Kiel 24105, Germany

2. Department of Congenital Heart Disease and Pediatric Cardiology, University Hospital Schleswig-Holstein , Arnold-Heller str. 3 , Kiel 24105, Germany

Abstract

Abstract Background In patients with a total cavopulmonary connection in Fontan circulation, the access to the common atrium (CA) during a catheter ablation can be challenging, even in the presence of fenestration in an intra-atrial lateral tunnel (IALT). In our department, the fenestration is typically marked with metal clips (MCs). To the best of our knowledge, there is no previous report of balloonoplasty of clipped fenestration. Case summary A 19-year-old male with hypoplastic left heart syndrome (HLHS) was scheduled for catheter ablation of recurrent atrial tachycardia. He was diagnosed with HLHS prenatally and underwent a stepwise surgical palliation. Fontan circulation was completed with the creation of a fenestrated IALT. The fenestration was marked by four MCs. During the ablation procedure, the passage of the steerable sheath with mapping catheter to the CA was prevented by a small fenestration size and rigidness of the edges of the fenestration caused by the MCs. Multiple attempts to dilate the fenestration using a peripheric angioplasty balloon failed. Only angioplasty with the ‘balloon-against-dilator’ technique was finally successful. Activation map showed a counterclockwise atrial flutter in the CA; successful ablation was performed. Discussion We present a case of challenging access to the CA through a clipped fenestration in a polytetrafluoroethylene baffle for atrial tachycardia ablation. Even though a tunnel fenestration in Fontan patients facilitates access to the CA, the passage of a steerable introducer with a mapping catheter may be challenging due to diameter mismatch and the rigidity of its edges caused by MCs. The balloon-against-dilator technique might be helpful when conventional balloon angioplasty fails.

Publisher

Oxford University Press (OUP)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Flecainide/β-adrenergic-receptor-antagonists;Reactions Weekly;2024-03-23

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3