Functional assessment of tandem coronary artery stenosis by intracoronary optical coherence tomography-derived virtual fractional flow reserve: a case series

Author:

Okuya Yoshiyuki1ORCID,Seike Fumiyasu2ORCID,Yoneda Kohei1,Takahashi Takefumi1,Kishi Koichi1,Hiasa Yoshikazu1

Affiliation:

1. Department of Cardiovascular Medicine, Tokushima Red Cross Hospital, 103 Irinoguchi, Komatsushima-cho, Komatsushima, Tokushima, Japan

2. Department of Cardiology, Pulmonology, Hypertension, and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan

Abstract

Abstract Background Optical coherence tomography (OCT)-derived fractional flow reserve (FFR)—which may be calculated using fluid dynamics—demonstrated an excellent correlation with the wire-based FFR. However, the applicability of the OCT-derived FFR in the assessment of tandem lesions is currently unclear. Case summary We present two cases of tandem lesions in the mid segment of the left anterior descending (LAD) artery which could have assessed accurately by OCT-derived FFR. The first patient underwent wire-based FFR at the far distal site of LAD, showed a value of 0.66. The OCT-derived FFR was calculated, yielding a value of 0.64. In the absence of stenosis at the proximal lesion, the OCT-derived FFR was calculated as 0.79, which was as same as the wire-based FFR obtained after stenting to the proximal lesion. Thus, additional stenting was performed at the distal lesion. The second patient underwent wire-based FFR at the far distal site of LAD, showed a value of 0.76 which was as same vale as OCT-derived FFR. Considering the absence of stenosis in the proximal lesion, the OCT-derived FFR was estimated as 0.88. After coronary stenting in the proximal lesion, the wire-based FFR yielded a value of 0.90. Therefore, additional intervention to the distal lesion was deferred. Discussion The described reports are the first two cases which performed physiological assessment using OCT in tandem lesions. The OCT-derived FFR might be able to estimate the wire-based FFR and the severity of each individual lesion in patients with tandem lesions.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Intravascular Imaging-Based Physiologic Assessment;Interventional Cardiology Clinics;2023-04

2. Physiological Assessment of Coronary Lesions in 2020;Current Treatment Options in Cardiovascular Medicine;2020-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3