Affiliation:
1. Department of Cardiology, Rems-Murr-Klinikum Winnenden , Am Jakobsweg 1, 71364 Winnenden , Germany
Abstract
Abstract
Background
We report a case of a 72-year-old patient developing a significant tricuspid regurgitation (TR) 6 years after a left ventricular assist device (LVAD) implantation. The aim of this case is to demonstrate the feasibility of transcatheter edge-to-edge repair (TEER) of the tricuspid valve and the excellent clinical benefit in long-term follow-up in an LVAD patient.
Case summary
Our patient presented with recurrent acute heart failure syndrome. After a fulminant myocarditis in 2005, his previous treatment consisted of cardiac resynchronization therapy, TEER of the mitral valve, and LVAD (HeartMate III) implantation. At that point in time, his TR was only mild to moderate. Due to recurrent hospitalization despite optimized heart failure medication, we decided to treat the patient with a tricuspid TEER. His immediate post-interventional result and 1-year follow-up showed an excellent outcome with only minimal TR on transoesophageal echocardiogram.
Discussion
In general, TR improves after LVAD implantation. However, there are two possible pathophysiological mechanisms, which result in an increasing TR: firstly, supporting LV dysfunction may lead to a leftward shift of the interventricular septum with restriction of the tricuspid leaflets. Secondly, the increase of venous preload with LVAD support may result in an annular dilatation with secondary TR, particularly in patients with pre-existing right ventricular dysfunction. According to the data currently available, the unpredictable course of developing TR necessitates regular clinical examination and echocardiographic investigation. Treatment with TEER appears to be feasible and safe, with excellent 1-year results in patients with previously implanted LVADs.
Publisher
Oxford University Press (OUP)