Abstract

Abstract Background Ascending aortic pseudoaneurysm due to coronary button dehiscence is a rare, yet life-threatening complication of reconstructive cardiac surgery. Because of its rare entity, large data are lacking, and therefore, treatment guidelines are missing. Case summary We describe a case of a 53-year-old male with a past medical history of ascending aortic aneurysm and severe aortic regurgitation who underwent Bentall procedure with 26 mm conduit and mechanical aortic valve 1 year before. Follow-up chest computed tomography (CT) revealed coronary button dehiscence with a giant aortic root pseudoaneurysm and mural thrombus inside. Given the risk of rupture, the heart team decided to go for a percutaneous approach. Based on a pre-interventional 3D reconstructed CT scan and guided by transoesophageal echocardiography and intravascular ultrasound, the pseudoaneurysm was successfully occluded with a 6 × 4 mm Amplatzer Duct Occluder II and simultaneous left main coronary artery (LMCA) stenting with a 4.0 × 15 mm drug-eluting stent. Post-procedural chest CT and echocardiography revealed minimal contrast leakage posterior to the aortic root and para LMCA region, confirmed thrombosis formation post occluder and stent deployment, and patent flow of LMCA. Discussion We describe the successful 3D reconstructed CT scan and peri-procedural transoesophageal echocardiography–guided percutaneous treatment of a giant aortic root pseudoaneurysm with an occluder and a drug-eluting stent with excellent results.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine

Reference13 articles.

1. Percutaneous closure of aortic pseudoaneurysm by Amplatzer occluder device-case series of six patients;Hussain;Catheter Cardiovasc Interv,2009

2. Valve-related events after aortic root replacement with cryopreserved aortic homografts;Kaya;Ann Thorac Surg,2005

3. Endovascular closure of thoracic aortic pseudoaneurysms: a combined device occlusion and coil embolization technique in patients unsuitable for surgery or stenting;Lyen;Catheter Cardiovasc Interv,2016

4. Transcatheter closure of aortic anastomosis leak resulting in patent Cabrol shunt after aortic replacement;Pu;JACC: Cardiovasc Interv,2017

5. Post-Bentall ascending aortic pseudoaneurysm due to coronary button dehiscence;Sivakumar;Ann Thorac Surg,2021