First successful transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve facilitated by fracturing of the leaflets: a case report

Author:

Butter Christian1,Kühnel Ralf-Uwe2,Hölschermann Frank1

Affiliation:

1. Department of Cardiology, Heart Centre Brandenburg Bernau & Faculty of Health Sciences Brandenburg, Brandenburg Medical School (MHB), Theodor Fontane, Ladeburger Straße 17, 16321 Bernau bei Berlin, Germany

2. Department of Cardio-thoracic Surgery, Heart Centre Brandenburg Bernau, Brandenburg Medical School (MHB), Bernau bei Berlin, Germany

Abstract

Abstract Background Degenerated and failed bioprosthetic cardiac valves can safely be treated with transcatheter valve-in-valve implantation in patients at high risk for reoperation. So far, non-functional mechanical valves must be treated with a surgical redo. Breaking the carbon leaflets before implanting a transcatheter valve into the remaining ring has never been described before. Case summary Here, we present the case of a 65-year-old male patient with severe heart failure, poor left ventricular function based on a fully immobile disc of his mechanical bileaflet aortic valve implanted 7 years ago. After the heart team declined to reoperate the patient due to his extremely high risk, we considered a transcatheter valve-in-valve implantation as the ultimate treatment approach. After successful interventional cracking of the leaflets in vitro, this approach, together with implanting a balloon-expandable transcatheter aortic valve replacement (TAVR) into the remaining ring, was performed under cerebral protection. The intervention resulted in a fully functional TAVR, improvement of heart function, and early discharge from the hospital. Discussion This case demonstrates the possibility to implant a transcatheter valve successfully into a non-functional mechanical bileaflet aortic prosthesis after fracturing the carbon discs while the brain is protected by a filter system. Critical steps of the procedure were identified. This new therapeutic approach might be offered to a limited patient cohort who is not eligible for a surgical redo.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Biologische vs. mechanische Klappenprothese;Zeitschrift für Herz-,Thorax- und Gefäßchirurgie;2021-10-27

2. Transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve: are we looking for trouble?;European Heart Journal - Case Reports;2021-08-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3