Development, Robustness by Design Expert and Validation of a Method for Enantiomeric Impurity Content Determination in Pretomanid Drug Substance and Pharmaceutical Dosage Form

Author:

Surapuraju Pavan Kumar Raju1ORCID,Juturu Raveendra Reddy2

Affiliation:

1. Department of Pharmaceutical Sciences, Jawaharlal Nehru Technological University Anantapur , Anantapuram, Andhra Pradesh 515002 , India

2. Raghavendra Institute of Pharmaceutical Education and Research , K.R.Palli Cross, Chiyyedu, Anantapuram, Andhra Pradesh 515721 , India

Abstract

Abstract For the purpose of identifying enantiomeric impurities in the drug substance and pharmaceutical dosage forms of the novel anti-TB medication pretomanid, an RP-high-performance liquid chromatography method was devised. To ensure the robustness of the optimized approach, analytical quality by design was used. Studies on factor screening and risk evaluation helped pinpoint the critical method parameters (CMPs); resolution (R1), analyte retention time (R2) and tailing factor (R3) are those terms. Pareto charts, half-normal plots, 3D surface plots, 2D contour plots and 3D cube plots were used to study the effects of solo and interactive CMPs on critical analytical attributes. Analysis of variance (ANOVA) was used to verify the technique parameters’ confirmation of significance (P = 0.05). With a Chiral Cel OJ-3R (150 × 4.6 mm, 3 µm) and a mobile phase consisting of 20 mM of ammonium trifluoroacetate, pH = 2.5, and acetonitrile in a gradient mode, chromatographic separation was accomplished. At 30°C and 330 nm, the column’s temperature and wavelength, respectively, were recorded. The procedure is stability-indicating and is LC–MS compatible. According to the International Conference on Harmonization tripartite guidelines, the method demonstrated appropriate specificity, sensitivity, linearity, accuracy, precision and robustness. The LOD and LOQ were, respectively, 0.09 and 0.3 μg/mL. With a correlation coefficient of >0.990, it was discovered that the established method for enantiomeric impurity was linear over the concentration range of 0.3–2.25μg/mL. The approach exhibits adequate accuracy (%recovery = 85–115%), robustness (%RSD = 5.0) and precision (%RSD = 5.0). The method was also shown to be stability-indicating and was shown to provide effective separation in the presence of degradation products through the use of forced degradation tests.

Publisher

Oxford University Press (OUP)

Subject

General Medicine,Analytical Chemistry

Reference30 articles.

1. The importance of stereoselective determination of drugs in the clinical laboratory;Rentsch;Journal of Biochemical and Biophysical Methods,2002

2. Design and development of chiral reagents for the chromatographic determination of chiral alcohols;Walther;Chirality,1996

3. Chiral drugs: an overview;Lien;International Journal of Biomedical Sciences,2006

4. Chirality of bioagents in protein binding storage and transport processes;Simonyi;Trends in Pharmacological Sciences,1986

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3