Development and Validation of Facile RP-HPLC Method for Simultaneous Determination of Timolol Maleate, Moxifloxacin Hydrochloride, Diclofenac Sodium and Dexamethasone in Plasma, Aqueous Humor and Pharmaceutical Products

Author:

Shahzad Aqeel1234ORCID,Arshad Sohail34,Zubair Faryal1234,Shahzad Shakeel56,Batool Farzana34,Fu Qiang12ORCID

Affiliation:

1. Department of Pharmaceutical Analysis , School of Pharmacy, , Xi’an 710061 , China

2. Xi’an Jiaotong University , School of Pharmacy, , Xi’an 710061 , China

3. Department of Pharmaceutics , Faculty of Pharmacy, , Multan, 60800 , Pakistan

4. Bahauddin Zakariya University , Faculty of Pharmacy, , Multan, 60800 , Pakistan

5. Institute of Microbiology, University of Agriculture Faisalabad , Punjab 38040 , Pakistan

6. Faculty of Medicine and Health, University of New South Wales Sydney , NSW 2052 , Australia

Abstract

Abstract The present study aimed to develop a validated RP-HPLC method for the simultaneous determination of timolol maleate (TM), moxifloxacin hydrochloride (MOXI), diclofenac sodium (DS) and dexamethasone (DEXA) in human plasma, bovine aqueous humor and pharmaceutical preparations. The chromatographic separation was studied using the C18 column. The chromatographic conditions, such as composition, pH, the flow rate of mobile phase, the temperature of column, wavelength of absorption and injection volume of the sample, were studied. The method was validated to confirm specificity, linearity and accuracy in accordance with an International Conference on Harmonization guidelines. The optimum conditions for separation included mobile phase 0.05 M monobasic phosphate buffer: acetonitrile (65:35 v/v), pH of buffer adjusted to 6.2 and the flow rate of 1 mL/minute. The optimum temperature of the column was found to be 35°C, absorption wavelength 265 nm and injection volume 50 μL. The baseline separation of all four drugs with good sensitivity, resolution, and a less than 15 min run time was achieved. The retention time of TM, MOXI, DS and DEXA were 4.3,5.7,9.9 and 13.5 minutes respectively. The limit of detection (LOD) values were 6.2, 4.8, 0.8 and 1.2 ng/mL for TM, MOXI, DS and DEXA, respectively, whereas their respective limit of quantification (LOQ) values was: were 42.6, 26.8, 5.6 and 6.2 ng/mL. The coefficient of variation for intra-day and inter-day were in the range of 0.32–1.57 and 1.29–3.07%, respectively. The method was found to be sensitive, precise and accurate in human plasma and bovine aqueous humor and can be applied for the quantification of these compounds in plasma, aqueous humor and pharmaceuticals.

Publisher

Oxford University Press (OUP)

Subject

General Medicine,Analytical Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3