Beta-Alanine and Tris-(hydroxyl methyl) Aminomethane as Peak Modifiers in the Development of RP–HPLC Methods Using Aceclofenac and Haloperidol Hydrochloride as Exemplar Drugs

Author:

Peraman Ramalingam1,Chiranjeevi Pokuri1ORCID,Reddy Yerrigamreddy Padmanabha1,Kumar Kondreddy Vinod1,Vasantharaju S G2,Nagappan Krishnaveni3

Affiliation:

1. Department of Pharmaceutical Analysis & Quality Assurance, Raghavendra Institute of Pharmaceutical, Education and Research, K.R.Palli Cross, Dist Anantapuramu, Chiyyedu 515721 India

2. Department of Pharmaceutical Quality Assurance, Manipal College of Pharmaceutical Sciences, Manipal, MAHE, Madhava Nagara, Manipal 576104, India

3. Department of Pharmaceutical Analysis, JSS College of Pharmacy, Ooty (A Constituent College of JSS Academy of Higher Education & Research), Udhagamandalam, Tamilnadu-643001, India

Abstract

Abstract In the present analytical approach, beta-alanine (ALA) and tris-(hydroxyl methyl) aminomethane (TRIS) were investigated as peak modifiers due to their water solubility and their possible peak modifying a property. These reagents were tested for their efficacy on the elution of aceclofenac (ACF) and haloperidol hydrochloride (HLC) from C18 column (250 mm × 4.6 mm, 5 μ) equipped with a photodiode array detector. The test reagents were investigated at 0.25 ± 0.05% concentration with a varying % aqueous composition on elution efficacy of HLC and ACF. The added ALA/TRIS in the mobile phase significantly (P < 0.05) improvised the symmetrical elution of HLC with 3-fold theoretical plates increase (P < 0.05) and 10-fold reduced capacity factor as compared to the control run. For ACF, the shoulder effect observed for ACF peak was eliminated. The optimized mobile phase was a combination of acetonitrile and water containing 0.25% beta-alanine/TRIS (pH 3.5 with ortho-phosphoric acid) at the ratio of 70:30 and 60:40% v/v, respectively, for ACF and HLC. The method was validated as per ICHQ2 guidelines. The column performance was tested for reproducibility in non-peak modifier applications and revealed a null effect on the column, thus these agents are relatively less toxic to HPLC columns.

Funder

DST-FIST

Publisher

Oxford University Press (OUP)

Subject

General Medicine,Analytical Chemistry

Reference32 articles.

1. Stationary and mobile phases in hydrophilic interaction chromatography: A review;Pavel;Analytica Chimica Acta,2011

2. Application of ion pairing chromatography to the analysis of inorganic analytes: Review;Teresa;Journal of Liquid Chromatography and Related Technologies,2007

3. Retention mechanism for ion-pair chromatography with chaotropic reagents;Cecchia;Journal of Chromatography. A,2006

4. Tetrazole-functionalized silica for hydrophilic interaction chromatography of polar solutes;Xiaojun;Chromatographia,2011

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献