Determination of Urea in Swimming Pool Water Using High-Performance Liquid Chromatography with Online Postcolumn Derivatization by Xanthydrol

Author:

Zhou Jinsen1ORCID,Liu Cimin1,Chen Yong2,Luo Xiaoyan3,Deng Dongsheng45

Affiliation:

1. Laboratory Department , Guangzhou Huangpu Center for Disease Control and Prevention, Xinyang West Road 23, Guangzhou 510530, P. R. China

2. Guangdong Provincial Engineering Research Center for Reverse Engineering of Industrial Additives , Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center,Guangzhou), Xianlie Middle Road 100, Guangzhou 510070, P. R. China

3. Physical and Chemical Inspection Department , Guangzhou Center for Disease Control and Prevention, Qide Road 1, Guangzhou 510440, P. R. China

4. College of Chemistry and Chemical Engineering , , Luoyang 471934, P. R. China

5. Luoyang Normal University , , Luoyang 471934, P. R. China

Abstract

Abstract A reversed-phase isocratic elution high-performance liquid chromatography method coupled with fluorescence detection has been developed to determine urea concentration via online postcolumn derivatization. Swimming pool water samples were filtered through 0.20 μm syringe filters. When the temperature of reaction coil was 40°C, urea was derivatized well with xanthydrol methanol solution (0.1 g/L) containing 0.50% hydrochloric acid with a flow rate of 0.20 mL/min. Successful separation was achieved by using Shim-pack VP-ODS C18 (250 mm × 4.6 mm, 5 μm) column, with a mobile phase containing phosphoric acid solution (0.01 mol/L) at a flow rate of 0.80 mL/min. Retention time and external standard method were used for qualitative and quantitative urea analysis, respectively. Under the established conditions, the limit of detection, linear range, correlation coefficient, recovery and relative standard deviation was 0.09 mg/L, 1.0–100.0 mg/L, 0.9998, 87.0–105.3% and 0.95–4.8%, respectively. Ammonia, thiourea and trichloroisocyanuric acid did not interfere with urea analysis. The method showed satisfactory results with high precision, accuracy, recovery, as well as sensitivity, for the determination of urea in swimming pool water.

Funder

Guangdong Medical Science and Technology Research Fund

Publisher

Oxford University Press (OUP)

Subject

General Medicine,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3