A Novel RP-HPLC Method for Simultaneous Estimation of Vilanterol Trifenatate, Umeclidinium Bromide and Fluticasone Furoate in Inhalation Dry Powder Formulation

Author:

Yadav Shweta1,Jain Vandana1ORCID,Magar Hemant2,Kumar M Vijay2,Warde Sayali2,Singh Raman Mohan2

Affiliation:

1. Department of Quality Assurance, Oriental College of Pharmacy , Sanpada, Navi Mumbai 400705 , India

2. Central Drug Testing Laboratory-Mumbai , Zonal FDA Bhawan, GMSD Compound, Belasis, Mumbai 400008 , India

Abstract

Abstract The dry powder inhalation formulation containing vilanterol trifenatate, umeclidinium bromide and fluticasone furoate intended for the therapy of bronchospasm related to chronic obstructive pulmonary disease and bronchial asthma was selected for the development and validation of a novel, selective, accurate, precise, quick and cost-efficient reversed-phase, high-performance liquid chromatography method. Neither an official monograph nor a single method has yet been published for the simultaneous estimation of these three compounds, which makes this method novel. The stationary phase of an ACE-C18-PFP column (250 mm × 4.6 mm, 5 μ) was used with a mobile phase of 25-mM sodium perchlorate buffer (pH 2.5 adjusted with ortho-phosphoric acid) and acetonitrile (40:60% v/v) at a flow rate of 1 mL/min to optimize chromatographic variables. The column temperature was kept at 40°C, and detection was at 224 nm, which was the isosbestic point of these three drugs. Well-resolved good peak symmetry was obtained for all three molecules by isocratic elution in less than 10 min, and the retention times of vilanterol trifenatate, umeclidinium bromide and fluticasone furoate were found to be 3.7, 5.4 and 8.3 min, respectively. The proposed method was validated as per ICH Q2 (R1) guidelines, and the calibration curves were linear in concentration ranges of 5–35 μg/mL for vilanterol trifenatate, 5–80 μg/mL for umeclidinium bromide and 5–150 μg/mL for fluticasone furoate, with mean % recoveries of 99–100%. The limits of detection and quantitation are 0.15 and 0.45 μg/mL for vilanterol trifenatate, 0.58 and 1.77 μg/mL for umeclidinium bromide and 0.32 and 0.96 μg/mL for fluticasone furoate, respectively. Hence, the proposed RP-HPLC technique was successfully used to quantify the inhalation formulation containing all three compounds.

Funder

Oriental College of Pharmacy and Central Drug Testing Laboratory

Publisher

Oxford University Press (OUP)

Subject

General Medicine,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3