2D or Synthetic 2D? A Reader Study of Visualization of Amorphous Calcifications

Author:

Renaldo Andrew1,Miller Matthew1,Caley Matthew1,Ganti Ramapriya1,Patrie James2,Rochman Carrie1,Nguyen Jonathan V1

Affiliation:

1. University of Virginia Health System, Department of Radiology and Medical Imaging, Charlottesville, VA, USA

2. University of Virginia School of Medicine, Department of Public Health Sciences, Charlottesville, VA, USA

Abstract

Abstract Objective Some vendors have created algorithms that generate synthetic 2D (s2D) images from a digital breast tomosynthesis (DBT) dataset to reduce the radiation from obtaining a separate 2D digital mammography (DM). This study evaluated the visibility of amorphous calcifications on 2D DM versus s2D on screening mammography. Methods This IRB-approved, retrospective, reader study included screening mammograms from 36 women who received screening DBT exams where both 2D DM and s2D images were obtained: 28 screening mammograms that were eventually given BI-RADS category 4 or 5 for amorphous calcifications and 8 BI-RADS category 1 or 2 screening exams. Two rounds of interpretation were conducted with a six-week washout period. Cases were randomized to display either the 2D DM or s2D images, which were then alternated in the second round. Four fellowship-trained breast radiologists determined whether a study merited recall for calcifications. If so, they rated calcification visibility on a scale of 1 to 5. McNemar chi-square tests were conducted to assess differences in recall rates and Wilcoxon signed rank tests were used to examine shifts in visibility. Results There was no difference in detection rates of amorphous calcifications between 2D DM and s2D, which were 75.9% and 75.0%, respectively (P = 1.000). Collectively, amorphous calcifications were more visible on s2D than 2D DM, with mean visibility scores of 3.4 versus 3.0, respectively (P = 0.005). Conclusion Synthetic 2D did not change identification of amorphous calcifications compared to 2D DM, and readers considered them more visible on average.

Funder

National Institutes of Health

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3