Gas Chromatographic/Nitrogen-Phosphorus Detection Method for Determination of Ethylene Thiourea in Finished Drinking Waters: Collaborative Study

Author:

Longbottom James E1,Edgell Kenneth W2,Erb Elizabeth J2,Lopez-Avila Viorica3, ,Brooks M,Byrne C,Clark D,Docus S,Kary K,Parker G,Perkins K,Pierri A,Quick F E,Simmons K,Torma L,Zimmerman D

Affiliation:

1. U.S. Environmental Protection Agency, 26 W. Martin Luther King Dr, Cincinnati, OH 45268

2. The Bionetics Corp., 16 Triangle Park Dr, Cincinnati, OH 45246

3. Mid-Pacific Environmental Laboratory, 625B Clyde Ave, Mountain View, CA 94043

Abstract

Abstract A joint U.S. Environmental Protection Agency (USEPA)-AOAC interlaboratory method validation study was conducted on USEPA National Pesticide Survey (NPS) Method 6, "Determination of Ethylene Thiourea (ETU) in Finished Drinking Water by Gas Chromatography with a Nitrogen-Phosphorus Detector." The purpose of the study was to determine and compare the mean recoveries and precision for determination of ETU in reagent water and finished drinking waters. The study design was based on Youden's nonreplicate plan for collaborative tests of analytical methods. The waters were spiked with ETU at 6 concentrations levels, prepared as 3 Youden pairs. In the method, the test water is extracted by passing the sample through an absorbent matrix type tube. ETU is recovered from the tube with methylene chloride, the extract is solvent-exchanged to ethyl acetate, and an aliquot of each extract is analyzed by gas chromatography using a nitrogen-phosphorus detector. Twelve laboratories participated in the study. Data were analyzed using a USEPA computer program, which measured recovery and precision for ETU and compared the performance of the method between the 2 water types. Over the concentration range tested, the mean percent recoveries of ETU were 82-92% in reagent water and 85-98% in finished drinking water. The range of the betweenlaboratory relative standard deviations (RSDR) for the 6 concentrations was 5-24% in reagent water, but was only 4-9% in finished drinking water. The range of the within-laboratory relative standard deviations (RSDr) was 6-14% for reagent water and 6- 10% for finished drinking water. Results for the 2 water matrixes showed no statistically significant differences. The method has been adopted first action by AOAC International for determination of ETU in finished drinking waters.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Pesticides in Water;Official Methods of Analysis of AOAC INTERNATIONAL;2023-01-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3