Three-dimensional printed hydrogel model vs cadaver: comparing inflatable penile prosthesis training and evaluation

Author:

Saba Patrick12,Cook Andrew12,Melnyk Rachel12,Schuler Nathan12,Holler Tyler12,Witthaus Michael1,Ralph David345,Collins Justin4,Bettocchi Carlo6,Van Renterghem Koenraad789,Ghazi Ahmed12

Affiliation:

1. University of Rochester Medical Center Department of Urology, , Rochester, NY 14642 , United States

2. University of Rochester Medical Center Simulation Innovation Laboratory, , Rochester, NY 14642 , United States

3. St Peters Andrology Centre, King Edward VII Hospital , London, W1G 6AA , United Kingdom

4. University College London , London, WC1E 6BT , United Kingdom

5. EAU Section of Genitourinary Reconstructive Surgeons , Arnhem, NL-6803 AA, Th e Netherlands

6. University of Bari Cattedra di Urologia–Policlinico, , Bari, 70124 , Italy

7. Department of Urology, Jessa Ziekenhuis–Campus Salvator , Hasselt, 3500 , Belgium

8. Hasselt University Faculty of Medicine, , Hasselt, 3500 , Belgium

9. Department of Urology, University Hospitals Leuven , Zonhoven, 3520 , Belgium

Abstract

Abstract Background Penile prosthesis implantation offers a durable, safe, and effective treatment option for male erectile dysfunction; however, many urologists feel apprehensive and uncomfortable placing penile prostheses due to limited training, low surgical experience, and intra- and postoperative complication management. Aim To compare a previously validated hydrogel inflatable penile prosthesis (IPP) training model with cadaver simulations across 4 main categories: anatomic replication and realism, procedural replication and realism, educational effectiveness, and efficacy and safety. Methods An overall 88 participants (15 attendings, 18 fellows, and 55 residents) performed guided IPP placements on a cadaver and a hydrogel model. Based on a 5-point Likert scale, postsurveys were used to assess the participants’ opinions regarding anatomic replication and realism, procedural replication and realism, educational effectiveness, and safety between the hydrogel model and cadavers. Outcomes A direct head-to-head scenario was created, allowing participants to fully utilize the hydrogel model and cadaver, which ensured the most accurate comparison possible. Results A total of 84% agreed that the hydrogel model replicates the relevant human cadaveric anatomy for the procedure, whereas 69% agreed that the hydrogel tissue resembles the appearance of cadaveric tissue. Regarding the pubic bone, outer skin, corporal bodies, dartos layer, and scrotum, 79%, 74%, 82%, 46%, and 30% respectively agreed that the hydrogel tissue resembled the texture/behavior of cadavers. Furthermore, 66% of participants agreed that the hydrogel model replicates all the procedural steps. Specifically, participants agreed that the model replicates the skin incision/dartos dissection (74%), placement of stay suture and corporotomy (92%), corporal dilation (81%), measurement of prosthetic size (98%), reservoir placement (43%), IPP placement (91%), scrotal pump placement (48%), and skin closure (51%). Finally, 86%, 93%, and 78% agreed that the hydrogel model is useful for improving technical skills, as a teaching/practicing tool, and as an evaluation tool, respectively. To conclude, 81% of participants stated that they would include the hydrogel model platform in their current training. Clinical Implications By replicating the IPP procedure, the hydrogel model offers an additional high-fidelity training opportunity for urologists, allowing them to improve their skills and confidence in placing penile prostheses, with the goal of improving patient surgical outcomes. Strengths and Limitations The hydrogel training model allows users to perform the entire IPP placement procedure with high anatomic realism and educational effectiveness, maintaining many of the high-fidelity benefits seen in cadavers while improving safety and accessibility. Conclusion Ultimately, this high-fidelity nonbiohazardous training model can be used to supplement and bolster current IPP training curriculums.

Funder

Coloplast

Publisher

Oxford University Press (OUP)

Subject

Urology,Reproductive Medicine,Endocrinology,Endocrinology, Diabetes and Metabolism,Psychiatry and Mental health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3