Development and validation of 3-dimensional simulators for penile prosthesis surgery

Author:

Reisman Yacov12,van Renterghem Koen3,Meijer Boaz4,Ricapito Anna5,Fode Mikkel6,Bettocchi Carlo5

Affiliation:

1. Flare-Health, Amsterdam , the Netherlands

2. Reuth Rehabilitation Hospital , Tel-Aviv 67062 , Israel

3. Department of Urology, Jessa Hospital , 3500 Hasselt , Belgium

4. Department of Urology, Acibadem Medical Center , 1043, HP Amsterdam , the Netherlands

5. Andrology and Male Genitalia Reconstructive Surgery Unit, University of Foggia , 71122, Foggia FG , Italy

6. Department of Urology, Herlev and Gentofte Hospital, University of Copenhagen , 13DK-2730, Herlev , Denmark

Abstract

Abstract Background The acquisition of skills in penile prosthesis surgery has many limitations mainly due to the absence of simulators and models for training. Three-dimensional (3D) printed models can be utilized for surgical simulations, as they provide an opportunity to practice before entering the operating room and provide better understanding of the surgical approach. Aim This study aimed to evaluate and validate a 3D model of human male genitalia for penile prosthesis surgery. Methods This study included 3 evaluation and validation stages. The first stage involved verification of the 3D prototype model for anatomic landmarks compared with a cadaveric pelvis. The second stage involved validation of the improved model for anatomic accuracy and teaching purposes with the Rochester evaluation score. The third stage comprised validation of the suitability of the 3D prototype model as a surgical simulator and for skill acquisition. The third stage was performed at 3 centers using a modified version of a pre-existing, validated questionnaire and correlated with the Rochester evaluation score. Outcome We sought to determine the suitability of 3D model for training in penile prosthesis surgery in comparison with the available cadaveric model. Results The evaluation revealed a high Pearson correlation coefficient (0.86) between questions of the Rochester evaluation score and modified validated questionnaire. The 3D model scored 4.33 ± 0.57 (on a Likert scale from 1 to 5) regarding replication of the relevant human anatomy for the penile prosthesis surgery procedure. The 3D model scored 4.33 ± 0.57 (on a Likert scale from 1 to 5) regarding its ability to improve technical skills, teach and practice the procedure, and assess a surgeon’s ability. Furthermore, the experts stated that compared with the cadaver, the 3D model presented greater ethical suitability, reduced costs, and easier accessibility. Clinical implications A validated 3D model is a suitable alternative for penile prosthesis surgery training. Strengths and limitations This is the first validated 3D hydrogel model for penile prosthesis surgery teaching and training that experts consider suitable for skill acquisition. Because specific validated guidelines and questionnaires for the validation and verifications of 3D simulators for penile surgery are not available, a modified questionnaire was used. Conclusion The current 3D model for penile prosthesis surgery shows promising results regarding anatomic properties and suitability to train surgeons to perform penile implant surgery. The possibility of having an ethical, easy-to-use model with lower costs and limited consequences for the environment is encouraging for further development of the models.

Funder

Zorgniotti

International Society forSexual Medicine

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3