Quantifying biological effects of radiation from high-energy linear accelerators on lymphocytes

Author:

Farkas Gyöngyi1,Kocsis Zsuzsa S1,Székely Gábor1,Mihály Dalma2,Pesznyák Csilla3,Pócza Tamás2,Major Tibor2,Polgár Csaba4,Jurányi Zsolt1

Affiliation:

1. National Institute of Oncology, Centre of Radiotherapy, Department of Radiobiology and Diagnostic Onco-Cytogenetics, 1122 Budapest, Ráth György u.7-9

2. National Institute of Oncology, Centre of Radiotherapy, 1122 Budapest, Ráth György u.7-9

3. Budapest University of Technological Economics Hungary, National Institute of Oncology, Centre of Radiotherapy, 1122 Budapest, Ráth György u.7-9

4. Centre of Radiotherapy, National Institute of Oncology, Budapest, Hungary, Department of Oncology, Semmelweis University, Budapest, Hungary, 1122 Budapest, Ráth György u.7-9

Abstract

ABSTRACT The aim of this study was to investigate the radiobiological effects of flattening filter (FF) and flattening filter-free (FFF) modes of linear electron accelerators and to understand whether there is any difference between the effects of these modes. We evaluated the number of chromosome aberrations following irradiation of lymphocytes from healthy volunteers with X-ray photons at two energy levels, 6 and 10 MV; the dose rate ranged between 5.50 and 23.08 Gy/min and absorbed doses ranged between 0.5 and 8 Gy. A 60Co curve was employed for comparison. Metaphases from the lymphocyte cultures were prepared using standard cytogenetic techniques and chromosome analysis was performed. Our results allow the performance of biodosimetry at higher energies and doses than the currently used reference dosimetry. We observed significant differences in aberration frequencies when different irradiation techniques were used. FFF mode has a higher radiobiological effect than the FF mode. Linear-quadratic dose response calibration curves were constructed and relative biological effectiveness (RBE) values were calculated. Average RBE values using 6 MV (5.50 Gy/min) as a reference radiation were 1.28 for 60Co γ irradiation, 1.11 for 6 FFF and 0.79–0.92 for 10 FFF. Since there are compelling differences between radiation modalities in cases of hypofractionation, these results may be even more important in a therapeutic situation. In case of an accidental overdose of a patient, use of the appropriate calibration curves for biodosimetry are also essential for quantifying the overdose.

Funder

national

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology Nuclear Medicine and imaging,Radiation