Affiliation:
1. Department of Orthodontics and Dentofacial Orthopaedics, Dental School, University of Heidelberg, Heidelberg, Germany
Abstract
Summary
Background
The integrity of orthodontic surface sealants after professional tooth cleaning (PTC) has previously only been evaluated in vitro. Recently, we have shown that optical coherence tomography (OCT) can successfully be used for the longitudinal assessments of sealant thickness in vitro and in vivo.
Objectives
Thus, the aim of the present study was to assess the sealant thickness after PTC in vitro and in vivo by OCT.
Trial design
Single-centre four-arm parallel-group randomized controlled trial.
Methods
Ninety-six extracted human teeth were randomly assigned to the surface sealants Pro Seal® (PS) and Opal® Seal™ (OS) and to PTC protocols: (1) polishing with brush and prophy paste (Cleanic®) or (2) erythritol air-polishing. Sealant thickness was assessed by OCT immediately after application (baseline), after thermocycling and after polishing for totals of 5, 10, 15, 30, 60, 90, and 120 seconds. Additionally, a clinical trial was conducted. Therefore, using a split-mouth design, quadrants of 20 patients and PTC protocols were randomized by an external randomization centre using computer generated tables to assign the surface sealants and PTC protocols. Sealant thicknesses were analysed at baseline, before and after PTC. Due to the optical properties of sealants, a complete blinding was not feasible.
Results
In vitro both sealants revealed significant layer thickness losses after both PTC protocols. PS lost 0.77 µm/s [95% CI (confidence interval): 0.67, 0.87] from air-polishing and 0.43 µm/s (95% CI: 0.37, 0.49) from polishing with brush while OS lost 0.44 µm/s (95% CI: 0.32, 0.55) from air-polishing and 0.79 µm/s (95% CI: 0.68, 0.89) from polishing with brush of layer thickness. Sealant thickness loss of was significantly higher after erythritol air-polishing for PS and after polishing with brush for OS. The results of a concurrent randomized controlled trial (RCT) were comparable to those achieved in the in vitro part of this study.
Limitations
Long-term surface sealant abrasion should be validated by additional RCTs.
Conclusions
For PTC on surface sealant treated teeth, low abrasive protocols should be used. Air-polishing should be avoided on PS protected teeth and polishing with brush on OS treated teeth.
Trial registration
ClinicalTrials.gov NCT03753256.
Funder
Wissenschaftsfond of the German Society of Orthodontics
Medical Faculty of Heidelberg University
Publisher
Oxford University Press (OUP)
Reference31 articles.
1. White-spot lesions during multibracket appliance treatment: a challenge for clinical excellence;Enaia;American Journal of Orthodontics and Dentofacial Orthopedics,2011
2. Changes in white spot lesions following post-orthodontic weekly application of 1.25 per cent fluoride gel over 6 months—a randomized placebo-controlled clinical trial. Part II: clinical data evaluation;Bock;European Journal of Orthodontics,2017
3. Changes in white spot lesions following post-orthodontic weekly application of 1.25 per cent fluoride gel over 6 months—a randomized placebo-controlled clinical trial. Part I: photographic data evaluation;Bock;European Journal of Orthodontics,2017
4. Interventions for orthodontically induced white spot lesions: a systematic review and meta-analysis;Höchli;European Journal of Orthodontics,2017
5. Long-term remineralizing effect of MI Paste Plus on regression of early caries after orthodontic fixed appliance treatment: a 12-month follow-up randomized controlled trial;Beerens;European Journal of Orthodontics,2018