Correcting cardiorespiratory noise in resting-state functional MRI data acquired in critically ill patients

Author:

Chan Suk-Tak1ORCID,Sanders William R2,Fischer David2,Kirsch John E1,Napadow Vitaly13,Bodien Yelena G23,Edlow Brian L12ORCID

Affiliation:

1. Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School , Charlestown, MA 02129 , USA

2. Center for Neurotechnology and Neurorecovery, Department of Neurology, Massachusetts General Hospital and Harvard Medical School , Boston, MA 02114 , USA

3. Department of Physical Medicine and Rehabilitation, Spaulding Rehabilitation Hospital, Harvard Medical School , Boston, MA 02129 , USA

Abstract

Abstract Resting-state functional MRI is being used to develop diagnostic, prognostic and therapeutic biomarkers for critically ill patients with severe brain injuries. In studies of healthy volunteers and non-critically ill patients, prospective cardiorespiratory data are routinely collected to remove non-neuronal fluctuations in the resting-state functional MRI signal during analysis. However, the feasibility and utility of collecting cardiorespiratory data in critically ill patients on a clinical MRI scanner are unknown. We concurrently acquired resting-state functional MRI (repetition time = 1250 ms) and cardiac and respiratory data in 23 critically ill patients with acute severe traumatic brain injury and in 12 healthy control subjects. We compared the functional connectivity results from two approaches that are commonly used to correct cardiorespiratory noise: (i) denoising with cardiorespiratory data (i.e. image-based method for retrospective correction of physiological motion effects in functional MRI) and (ii) standard bandpass filtering. Resting-state functional MRI data in 7 patients could not be analysed due to imaging artefacts. In 6 of the remaining 16 patients (37.5%), cardiorespiratory data were either incomplete or corrupted. In patients (n = 10) and control subjects (n = 10), the functional connectivity results corrected with the image-based method for retrospective correction of physiological motion effects in functional MRI did not significantly differ from those corrected with bandpass filtering of 0.008–0.125 Hz. Collectively, these findings suggest that, in critically ill patients with severe traumatic brain injury, there is limited feasibility and utility to denoising the resting-state functional MRI signal with prospectively acquired cardiorespiratory data.

Funder

National Institute of Health

National Institute of Neurological Disorders and Stroke

National Center for Complementary and Integrative Health

James S. McDonnell Foundation

Rappaport Foundation

Tiny Blue Dot Foundation

National Institute on Disability, Independent Living and Rehabilitation Research

Publisher

Oxford University Press (OUP)

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3