The use of simultaneous stereo-electroencephalography and magnetoencephalography in localizing the epileptogenic focus in refractory focal epilepsy

Author:

Vivekananda Umesh1ORCID,Cao Chunyan23,Liu Wei2,Zhang Jing2,Rugg-Gunn Fergus1,Walker Matthew C1ORCID,Litvak Vladimir3,Sun Bomin2,Zhan Shikun2

Affiliation:

1. Department of Clinical and Experimental Epilepsy, UCL, Queen Square Institute of Neurology, London WC1N 3BG, UK

2. Department of Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai 200025, China

3. Wellcome Centre for Human Neuroimaging, UCL, Queen Square, London WC1N 3AR, UK

Abstract

Abstract Both magnetoencephalography and stereo-electroencephalography are used in presurgical epilepsy assessment, with contrasting advantages and limitations. It is not known whether simultaneous stereo-electroencephalography–magnetoencephalography recording confers an advantage over both individual modalities, in particular whether magnetoencephalography can provide spatial context to epileptiform activity seen on stereo-electroencephalography. Twenty-four adult and paediatric patients who underwent stereo-electroencephalography study for pre-surgical evaluation of drug-resistant focal epilepsy, were recorded using simultaneous stereo-electroencephalography–magnetoencephalography, of which 14 had abnormal interictal activity during recording. The 14 patients were divided into two groups; those with detected superficial (n = 7) and deep (n = 7) brain interictal activity. Interictal spikes were independently identified in stereo-electroencephalography and magnetoencephalography. Magnetoencephalography dipoles were derived using a distributed inverse method. There was no significant difference between stereo-electroencephalography and magnetoencephalography in detecting superficial spikes (P = 0.135) and stereo-electroencephalography was significantly better at detecting deep spikes (P = 0.002). Mean distance across patients between stereo-electroencephalography channel with highest average spike amplitude and magnetoencephalography dipole was 20.7 ± 4.4 mm. for superficial sources, and 17.8 ± 3.7 mm. for deep sources, even though for some of the latter (n = 4) no magnetoencephalography spikes were detected and magnetoencephalography dipole was fitted to a stereo-electroencephalography interictal activity triggered average. Removal of magnetoencephalography dipole was associated with 1 year seizure freedom in 6/7 patients with superficial source, and 5/6 patients with deep source. Although stereo-electroencephalography has greater sensitivity in identifying interictal activity from deeper sources, a magnetoencephalography source can be localized using stereo-electroencephalography information, thereby providing useful whole brain context to stereo-electroencephalography and potential role in epilepsy surgery planning.

Funder

National Institute of Health Research, Epilepsy Research UK

Medical Research Council

Academy Medical Sciences

Wellcome Trust

National Natural Science Foundation of China

Publisher

Oxford University Press (OUP)

Subject

General Earth and Planetary Sciences,General Environmental Science

Reference20 articles.

1. Interictal and ictal source localization for epilepsy surgery using high-density EEG with MEG: A prospective long-term study;Plummer;Brain,2019

2. Magnetoencephalography for epileptic focus localization in a series of 1000 cases;Rampp;Brain J Neurol,2019

3. MEG and EEG in epilepsy: Is there a difference?;Guy;Physiol Meas,1993

4. A quantitative assessment of the sensitivity of whole-head MEG to activity in the adult human cortex;Hillebrand;NeuroImage,2002

5. Differentiability of simulated MEG hippocampal, medial temporal and neocortical temporal epileptic spike activity;Stephen;J Clin Neurophysiol,2005

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3