CHARACTERIZATION OF A LANTHANUM BROMIDE DETECTOR FOR EYE LENS DOSIMETRY AT THE CANDU NUCLEAR POWER PLANTS BASED ON DIRECT MEASUREMENTS OF THE GAMMA-RAY SPECTRA

Author:

Laranjeiro A S1,Bohra F1,Byun S H1,Atanackovic J12,Hanu A R13

Affiliation:

1. Department of Physics and Astronomy, McMaster University, 1280 Main St W, Hamilton, ON, L8S 4L8, Canada

2. Ontario Power Generation, 1549 Victoria St E, Whitby, ON, L1N 9E3, Canada

3. Bruce Power, 177 Tie Rd, Tiverton, ON, N0G 2T0, Canada

Abstract

Abstract Gamma-ray spectra were measured using a LaBr$_{3}$(Ce) spectrometer during the outage periods, aiming at quantifying the gamma source term of radiation workers’ exposure, at the CANDU nuclear power reactors, for the purposes of eye lens dosimetry. The spectra were measured inside the boiler rooms, of the Bruce Power and Ontario Power Generation (OPG) CANDU nuclear power plants, where workers are exposed to relatively high dose rates radiation fields during the maintenance work. Prior to measurements at the CANDU reactors, the pulse shaping parameters of the gamma spectrometer were optimised for high rates gamma fields, up to an input rates of 120 kcps, in order to accomplish a high output rate with a reasonable energy resolution. In parallel, the response of the LaBr$_{3}$(Ce) detector was characterized by experiments and Monte Carlo simulations. The gamma spectra measured at the CANDU reactors were reported in terms of the gamma-ray fluence rate spectrum. In all measured data, $^{60}$Co and $^{95}$Nb were main contributors of the gamma fields. The measured spectra have been used to calculate the dosimetric quantities of interest: personal dose equivalents H$_{p}$(10) and H$_{p}$(0.07) and eye lens absorbed dose.

Funder

Natural Sciences and Engineering Research Council of Canada

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference23 articles.

1. ICRP statement on tissue reactions/early and late effects of radiation in normal tissues and organs - threshold doses for tissue reactions in a radiation protection context;ICRP Publication 118;Ann. ICRP,2012

2. Radiation-induced cataracts: the Health Protection Agency’s response to the ICRP statement on tissue reactions and recommendation on the dose limit for the eye lens;Bouffler;J. Radiol. Prot.,2012

3. Report of IRPA task group on the impact of the eye lens dose limits;Cantone;J. Radiol. Prot.,2017

4. Optimization of radiophotoluminescent glass dosemeter for occupational eye lens dosimetry in interventional radiology/cardiology;Silva;Radiat. Prot. Dosimetry,2018

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献