The back-n project in China Spallation Neutron Source (CSNS) was launched primarily for nuclear data measurements. In the backscattering neutron hall, the neutron and gamma monitors were used for dose monitoring. Because of the dead time problem of monitors, performance of the monitors in such pulsed radiation field needs to be analyzed. In this research, experiments with dose monitors and personal dosemeters were conducted, and simulation by Monte Carlo code FLUKA was performed. Results showed that the values by monitors are smaller, and the larger the dose, the larger the difference. The reasons in term of energy response and dead time have been analyzed, and corrections were discussed. After corrections, the measured value can agree with the simulation results in the range of about a factor 3. Totally speaking, the values recorded by neutron and gamma monitors can be a reference for radiation safety management in CSNS.