DOES LOSS OF 131I COUNTS NEED CORRECTION IN GAMMA-CAMERA IMAGING IN CHILDREN AND YOUNG ADULTS IN POST-THERAPEUTIC SCANS? COMPARISON OF PHANTOM VERSUS PATIENT STUDY

Author:

Kumar Praveen1,Bal Chandrasekhar1,Damle Nishikant A1,Dwivedi S N2,Agarwala Sandeep3

Affiliation:

1. Department of Nuclear Medicine, All India Institute of Medical Sciences, 110029 New Delhi, India

2. Department of Biostatistics, All India Institute of Medical Sciences, 110029 New Delhi, India

3. Department of Pediatric Surgery, All India Institute of Medical Sciences, 110029 New Delhi, India

Abstract

Abstract This study aimed to verify whether there is whole-body (WB) count loss due to dead time of gamma camera when high amount of 131I is administered to patients. Planar views of a phantom containing 5751 MBq of 131I were acquired at 24-h intervals for 68 d. Eighty-two patients ≤21 y old were given diagnostic activity (74 MBq) followed by therapeutic activity (1110–5772 MBq). WB scans of patients were acquired at 2 h after diagnostic and therapeutic activity administration. Count loss in patients and phantom were compared. In phantom, there was no count loss up to 139 MBq. At maximum activity of 5751 MBq 131I, the loss was 46%. In patients, the average WB count loss was insignificant after the administration of therapeutic activity. Count loss due to dead time in phantom differed significantly from patient results that can probably be explained by the distribution of activity over a large area in vivo.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference18 articles.

1. Deadtime characteristics of anger cameras;Sorenson;J. Nucl. Med. Off. Publ. Soc. Nucl. Med.,1975

2. Methods of correcting anger camera deadtime losses;Sorenson;J. Nucl. Med. Off. Publ. Soc. Nucl. Med.,1976

3. Testing the count rate performance of the scintillation camera by exponential attenuation: decaying source; multiple filters;Adams;Med. Phys.,1988

4. Dead time of an anger camera in dual-energy-window-acquisition mode;Zasadny;Med. Phys.,1993

5. Correction of count losses due to deadtime on a DST-XLi (SmVi-GE) camera during dosimetric studies in patients injected with iodine-131;Delpon;Phys. Med. Biol.,2002