Abstract

Abstract Aims Contrast-enhanced computed tomography (CE-CT) is the gold standard for diagnosing acute aortic syndromes (AAS). Unenhanced computed tomography (unenhanced-CT) also provides specific findings for AAS; however, its diagnostic ability is not well discussed. This study aims to evaluate the potential of unenhanced-CT as an AAS screening tool. Methods and results We retrospectively examined AAS patients who visited our hospital between 2011 and 2021 to validate the diagnostic value of unenhanced-CT alone and along with the aortic dissection detection risk score (ADD-RS) plus D-dimer. Acute aortic syndrome was assessed as detectable using unenhanced-CT with any of the following findings: pericardial haemorrhage, high-attenuation haematoma, and displacement of intimal calcification or a flap. Of the 316 AAS cases, 292 (92%) were detectable with unenhanced-CT. Twenty-four (8%) cases undetectable with unenhanced-CT involved younger patients [median (interquartile range), 45 (42–51) years vs. 72 (63–80) years, P < 0.001] and patients more frequently complicated with a patent false lumen (79% vs. 42%, P < 0.001). Acute aortic syndrome-detection rate with unenhanced-CT increased with age, reaching 98% (276/282) in those ≥50 years of age and 100% (121/121) in those ≥75 years of age. With the ADD-RS plus D-dimer, there was only one AAS case undetectable with unenhanced-CT among patients ≥50 years of age, except for cases with the ADD-RS ≥1 plus D-dimer levels of ≥0.5 μg/mL. Conclusion Acute aortic syndromes in younger patients and patients with a patent false lumen could be misdiagnosed with unenhanced-CT alone. The combination of the ADD-RS plus D-dimer and unenhanced-CT could minimize AAS misdiagnosis while avoiding over-testing with CE-CT.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Critical Care and Intensive Care Medicine,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3